Delta Tau GEO BRICK DRIVE Benutzerhandbuch

Seite von 294
 Geo Brick Drive User Manual 
Pinouts and Software Setup 
 160 
+5V ENC PWR (Alternate Encoder Power) 
Typically, feedback devices are powered up through the X1-X8 connectors on the Geo Brick Drive using 
the internal +5VDC power supply. In some cases, feedback devices consume power excessively and risk 
of surpassing the internal power supply limitation.    
 
This  connector  provides  an  alternate  mean  to  power-up  the  feedback  devices  (+5V  only)  if  the  budget 
exceeds the specified thresholds. 
 
 
Note 
Encoders  requiring  other  than  +5VDC  power  must  be  supplied 
externally, and NOT through the X1-X8 connectors NOR through this 
+5VDC connector.    
 
G B
L
x
-
x
x
-
x
x
x
-
x
x
x
X
Add-in Board Options
x
X X X
 
 
The add-in board (any non-zero digit in the highlighted part number field) for MACRO and special 
feedback requires an additional ~ 0.5A (+5V power). This alters the total power available for encoders.    
 
The newer models of the Geo Brick Drive have a stronger power supply which can handle more (+5V) 
power drain. The following tables summarize the +5V power available for encoder devices (X1-X8):  
 
 
Caution 
The  maximum  current draw  out of a single  encoder channel  must not 
exceed 750 mA.  
 
Geo Brick Drive Model 
Total Encoder Power 
Available [Amps] 
Power Per Encoder 
(4 x channels) [mA] 
Power Per Encoder 
( 8 x channels) [mA] 
Older 
Newer 
Older 
Newer 
Older 
Newer 
Without Add-in Board 
1.5 
375 
500 
188 
250 
With Add-in Board 
1.5 
250 
375 
125 
188 
 
 
Note 
The  newer  models  were  introduced  in  October  of  2012,  and  can  be 
recognized by the 4-pin terminal block 24V logic with STO connector.