Receiving, Unpacking, and Mounting 
 20 
Mounting 
The location of the Geo  Brick LV is important.  Installation should be in an area that  is protected from 
direct  sunlight,  corrosives,  harmful  gases  or  liquids,  dust,  metallic  particles,  and  other  contaminants.  
Exposure to these can reduce the operating life and degrade performance of the drive. 
 
Several other factors should be carefully evaluated when selecting a location for installation: 
 
For effective cooling and maintenance, the Geo Brick LV should be mounted on a smooth, non- 
flammable vertical surface. 
 
At  least 76  mm  (3 inches) top and bottom clearance  must be provided for air flow.   At  least 10 
mm (0.4 inches) clearance is required between units (each side). 
 
Temperature, humidity and Vibration specifications should also be taken in account. 
 
!
Caution 
Unit must be installed in an enclosure that meets the environmental IP 
rating  of the  end product (ventilation  or cooling  may  be  necessary to 
prevent enclosure ambient from exceeding 45° C [113° F]). 
 
The  Geo  Brick  LV  can  be  mounted  with  a  traditional  3-hole  panel  mount,  two  U  shape/notches  on  the 
bottom and one pear shaped hole on top.  
If  multiple  Geo  Brick  LVs  are  used,  they  can  be  mounted  side-by-side,  leaving  at  least  a  122  mm 
clearance  between  drives.    This  means  a  122  mm  center-to-center  distance  (0.4  inches).  It  is  extremely 
important  that  the  airflow  is  not  obstructed  by  the  placement  of  conduit  tracks  or  other  devices  in  the 
enclosure. 
If the drive is mounted to a back panel, the back panel should be unpainted and electrically conductive to 
allow  for  reduced  electrical  noise  interference.    The  back  panel  should  be  machined  to  accept  the 
mounting bolt pattern of the drive. 
 
The  Geo  Brick  LV  can  be  mounted  to  the  back  panel  using  three  M4  screws  and  internal-tooth  lock 
washers.  It  is  important that the teeth break through  any anodization  on the  drive’s  mounting  gears to 
provide a good  electrically conductive path in as many places as possible.  Mount the  drive  on the back 
panel so there is airflow at both the top and bottom areas of the drive (at least three inches).