Appendix B: Serial Port Connections  
B-1 
B&B Electronics  --  PO Box 1040  --  Ottawa, IL  61350 
PH (815) 433-5100  --  FAX (815)  433-5104
 
APPENDIX B:  SERIAL PORT CONNECTIONS  
 
 
 
 
 
 
 
The next four sections will cover the required serial port 
connections on the 232SPS2.  Each section will list the required 
connections and the optional connections that some systems may 
require.  Connections to the serial port of the 232SPS2 are made on 
a female DB-25 connector.  
SERIAL TO PARALLEL MODE, HARDWARE HANDSHAKING                           
 
The serial port of the 232SPS2 module is wired as a DCE 
device.  For proper operation the following connections must be 
present: 
1.  Transmit Data (TD) from the host (DTE) must be 
connected to Pin #2 on the 232SPS2 module. 
2.  Data Set Ready (DSR) from the host must be 
connected to Pin #6 on the 232SPS2 module. 
3.  Signal Ground (SG) from the host must be 
connected to Pin #7 on the 232SPS2 module. 
If port powering the 232SPS2, these connections are 
recommended:  
4.  Request to Send (RTS) from the host must be 
connected to Pin #4 on the 232SPS2 module. 
5.  Data Terminal Ready (DTR) from the host must be 
connected to Pin #20 on the 232SPS2 module. 
Some software may require one or more of the following 
connections: 
6.  Clear To Send (CTS) from the host should be 
connected to Pin #5 on the 232SPS2 module. 
7.  Data Carrier Detect (DCD) from the host should be 
connected to Pin #8 on the 232SPS2 module. 
NOTE:  IBM PC’s (or compatible) serial ports and serial printers are 
both DTE devices.  Therefore, a null modem cable (like a serial 
printer cable!
) must be used when connecting a PC’s serial port to 
a printer.  A null modem cable or serial printer cable should not be 
used to connect to the 232SPS2 (unless your device is a DCE -- 
such as a modem). 
 
 
 
 
B-2 
Appendix B: Serial Port Connections 
232SPS2-3903 Manual 
B&B Electronics  --  PO Box 1040  --  Ottawa, IL  61350 
PH (815) 433-5100  --  FAX (815)  433-5104
 
SERIAL TO PARALLEL MODE, SOFTWARE HANDSHAKING 
For proper operation the following connections must be present: 
1.  Transmit Data (TD) from the host (DTE) must be 
connected to Pin #2 on the 232SPS2 module. 
2.  Receive Data (RD) from the host (DTE) must be 
connected to Pin #3 on the 232SPS2 module. 
3.  Signal Ground (SG) from the host must be 
connected to Pin #7 on the 232SPS2 module. 
If port powering the 232SPS2, these connections are 
recommended:  
4.  Request to Send (RTS) from the host must be 
connected to Pin #4 on the 232SPS2 module. 
5.  Data Terminal Ready (DTR) from the host must be 
connected to Pin #20 on the 232SPS2 module. 
Some software may require one or more of the following 
connections: 
6.  Data Set Ready (DSR) from the host must be 
connected to Pin #6 on the 232SPS2 module. 
7.  Clear To Send (CTS) from the host should be 
connected to Pin #5 on the 232SPS2 module. 
8.  Data Carrier Detect (DCD) from the host should be 
connected to Pin #8 on the 232SPS2 module. 
NOTE:  IBM PC’s (or compatible) serial ports and serial printers are 
both DTE devices.  Therefore, a null modem cable (like a serial 
printer cable!
) must be used when connecting a PC’s serial port to 
a printer.  A null modem cable or serial printer cable should not be 
used to connect to the 232SPS2 (unless your device is a DCE -- 
such as a modem).