Baumatic BO675TS Benutzerhandbuch

Seite von 28
GB
16
Touching any keys will not cause any acoustic feedback.
Failure declarations and error codes
The control is continuously checking the status of the system. If an abnormal condition is 
detected for more than 1 minute, a failure occurs:
-  The heaters and the other loads are disabled.
-  The display shows a “E” letter flashing, followed by a numeric code that depends on 
the kind of failure.
-  The control emits an acoustic warning signal that will last for some minutes.
To reset a failure declaration, first remove the cause of the failure then touch the [H] key 
(OFF).
Error code table.
Error
Description
E001
Temperature sensor shorted.
E008
Latch time-out overflow.
E016
Oven cavity overheating
E017
Temperature sensor disconnected or broken
E032
Wrong oven model configuration