Dimensions in parentheses are in
millimeters unless otherwise specified.
Planning Information
Pro 24"
(610)
Deep Wall Ventilation Hood
M O D E L   P W 3 0 2 4 1 8 ( R )
P R O   V E N T I L A T I O N   C F M   R E C O M M E N D A T I O N S
P R O   V E N T I L A T I O N   B L O W E R   O P T I O N S
Pro 24" (610) Deep Wall Hoods
Blower Description
Blower Number
Wall Hood Models
600 CFM Internal
WBLOWER-60INT (810559)
PW302418 / PW362418 / PW422418
900 CFM Internal
WBLOWER-90INT (811131)
PW302418 / PW362418 / PW422418
1200 CFM Internal
WBLOWER-120INT (810316)
PW482418 / PW542418 / PW602418 / PW662418
600 CFM In-Line
BLOWER-60IL (808331)
PW302418
1100 CFM In-Line
BLOWER-110IL (808332)
All 24" (610) Deep Wall Hoods
600 CFM Remote
BLOWER-60REM (801640)
PW302418
900 CFM Remote
BLOWER-90REM (801641)
PW302418 / PW362418 / PW422418
PW482418 / PW542418
1200 CFM Remote
BLOWER-120REM (801642)
All 24" (610) Deep Wall Hoods
1500 CFM Remote
BLOWER-150REM (804701)
All 24" (610) Deep Wall Hoods
Pro 24" (610) Deep Wall Hoods
Model
PW302418 PW362418 PW422418 PW482418 PW542418 PW602418 PW662418
DF304 / R304 / SRT304
600
600
DF366 / R366 / SRT366 / RT366
900
900
DF364 / R364 / SRT364 / RT364
900
900
RT362
900
900
R488 / RT488
1100
1100
DF486 / R486 / SRT486 / RT486
1100
1100
DF484 / R484 / SRT484 / RT484
1100
1100
DF606 / R606
1500
1500
DF604
1500
1500
Minimum CFM requirements for Wolf ranges and rangetops. CFM recommendations are based on total Btu/hr output.