Wolf PL522212 Benutzerhandbuch

Seite von 8
8
Dimensions in parentheses are in
millimeters unless otherwise specified.
Planning Information
Pro Ventilation Hood Liner
M O D E L   P L 5 2 2 2 1 2
P R O   V E N T I L A T I O N   C F M   R E C O M M E N D A T I O N S
P R O   V E N T I L A T I O N   B L O W E R   O P T I O N S
Pro Hood Liners
Blower Description
Blower Number
Hood Liner Models
1200 CFM Internal
LBLOWER-120INT (805087)
All Hood Liners
1100 CFM In-Line
BLOWER-110IL (808332)
All Hood Liners
900 CFM Remote
BLOWER-90REM (801641)
All Hood Liners
1200 CFM Remote
BLOWER-120REM (801642)
All Hood Liners
1500 CFM Remote
BLOWER-150REM (804701)
All Hood Liners
Pro Hood Liners
Model
PL342212
PL402212
PL462212
PL522212
PL582212
DF304 / R304 / SRT304
600
600
DF366 / R366 / SRT366 / RT366
900
900
DF364 / R364 / SRT364 / RT364
900
900
RT362
900
900
R488 / RT488
1100
1100
DF486 / R486 / SRT486 / RT486
1100
1100
DF484 / R484 / SRT484 / RT484
900
900
DF606 / R606
1500
DF604
1500
Minimum CFM requirements for Wolf ranges and rangetops. CFM recommendations are based on total Btu/hr output.
Additional CFM may be required for charbroilers, griddles and long duct runs.