Wolf AGE36 Merkblatt

Seite von 2
NOTE:  In line with its policy to continually improve its product, Wolf Range Company
reserves the right to change materials and specifications without notice.
This appliance is manufactured for commercial use only and is not intended for home use.
F-
36977 (02-08)
MODEL: AGE SERIES 
LOW PROFILE HEAVY-DUTY 
GAS GRIDDLE
INSTALLATION REQUIREMENTS:
1.  A  gas  pressure  regulator  supplied  with  the  unit  must  be 
installed:
   
Natural Gas 5.0" (127 mm) W.C.
   
Propane Gas 10.0" (254 mm) W.C.
2.  All models require a 6" (152 mm) clearance at both sides 
and  rear  adjacent  to  combustible  and  non-combustible 
construction.
3. These units are manufactured for installation in accordance 
with ANSI/NFPA-70, National Electrical code.
  An adequate ventilation system is required for Commercial 
Cooking  Equipment  (NFPA  No.  96).  Information  may  be 
 
 
 
 
OVERALL 
WORKING 
NO. OF 
TOTAL 
NO. OF 
APPROX.
 
MODEL 
WIDTH 
DEPTH 
HEIGHT* 
HEIGHT* 
BURNERS 
BTU/HR. 
DRAWERS** 
SHP.WT.
 
AGE24 
24" 
33" 
15½" 
11³⁄₈" 
60,000 
285 lbs./129 kg
 
AGE36 
36" 
33" 
15½" 
11³⁄₈" 
90,000 
400 lbs./181 kg
 
AGE48 
48" 
33" 
15½" 
11³⁄₈" 
120,000 
480 lbs./218 kg
 
AGE60 
60" 
33" 
15½" 
11³⁄₈" 
150,000 
650 lbs./295 kg
 
AGE72 
72" 
33" 
15½" 
11³⁄₈" 
180,000 
790 lbs./358 kg
*These are nominal dimensions and can vary by +1.75" with adjustable legs.
**All Rear Grease option griddles have only one (1) grease drawer on the left side.
obtained by writing to the National Fire Protection Association, 
Batterymarch Park, Quincy, MA 02169.
4.  These units are manufactured for installation in accordance 
with National Fuel Gas Code, ANSI-Z223.1/NFPA #54 (lat-
est edition). Copies may be obtained from The American 
Gas  Association,  Accredited  Standards  Committee  Z223 
@  400N.  Capital  St.  NW,  Washington,  DC  20001,  or  the 
Secretary Standards Council, NFPA, 1 Batterymarch Park, 
Quincy, MA 02169-7471.
 
 
NOTE: In the Commonwealth of Massachusetts
 
All  gas  appliances  vented  through  a  ventilation  hood  or 
exhaust system equipped with a damper or with a power 
means of exhaust shall comply with 248 CMR.
5. This appliance is manufactured for commercial installation 
only and is not intended for home use.