High End Systems High End LCD Controller for Studio Color Benutzerhandbuch

Seite von 272
Studio Color LCD Controller
Setting the Controller Voltage
1-9
1
Figure 1-1.  Location of the controller’s voltage 
selection switch and fuse.
Replacing the Fuse
You must replace the controller’s fuse whenever you change 
the voltage setting or after the fuse becomes damaged.  
Before attempting to replace the controller’s fuse, you must 
obtain a replacement fuse of the same type and rating.  Both 
fuses listed below are 5mm x 20mm.
115 V operation—use 0.5 A, 250 V, Slow Blow Only
230 V operation—use 0.3 A, 250 V, Slow Blow Only
1.
Unplug the controller from the power source.
2.
Using a small screwdriver, carefully push in on and turn the 
fuse holder counter-clockwise and remove it from the 
controller. The fuse holder is shown in Figure 1-1.
3.
Replace the fuse with one of the same type and rating only!
4.
Carefully insert the fuse holder back into the controller and 
retighten it by turning it clockwise.
5.
If this is a new controller, continue with Chapter 2.
DAT A LINK
OUT
PERSONA LIT Y
SLAVE
MASTE R
RS-232
SERIAL PORT
1-6
ANALOG INPUTS
7-12
REM OTE
ENABLE
FUS E
CAUTION
voltage
select
1 2  3 4
A
B
M ID I
I N
OUT
S TE RE O
A UD IO
INP UT
11
5
L
R
115 V 0.5 A, SLOW BLOW
230 V  0.315 A,  SLOW  BLOW
1 2  3 4
1 2  3 4 5  6 7 8
1 2  3 4 5  6 7 8
FUSE
CAUTION
voltage
select
23
0V