High End Systems High End LCD Controller for Studio Color Benutzerhandbuch

Seite von 272
Studio Color LCD Controller
Setting the Switches
2-7
2
Switch B-5:  Binary Preset Access
Switch B-5 Off (default) – (Twelve-level preset access.)  An 
analog controller accesses each of 8 presets on 12 
independent levels for a total of 96 presets.  You must also 
select preset level access by setting switch B-3 ON.  
Switch B-5 On – When switch B-5 is ON, an analog 
controller accesses the first 10 of the 12 analog input 
channels in binary combinations to provide remote access to 
1023 presets.  You must also select preset level access by 
setting switch B-3 ON.
Channels 11 and 12 control blackout and standby, as shown 
below:
Channel 11 (blackout):  closes all fixtures’ shutters but 
wheels and effects continue to run.
Channel 12 (standby):  activating channel 12 when the 
controller is in standby (Standby LED is ON) takes the 
controller out of standby.  Activating channel 12 when 
the controller is not in standby (Standby LED is OFF) has 
no effect.  When the controller is in standby, all fixtures’ 
shutters close and any in-progress wheel and effect 
changes stop immediately.  Controller pages continue to 
advance.
Switch B-6:  Dependent/Independent Presets
Switch 6 sets the mode of the presets as they relate to the 
master controller. 
Switch B-6 Off (default) – Dependent Presets; the controller 
behaves as follows:
The master controller’s master intensity setting controls 
slaves.
Slaved controllers’ modulation effects respond to audio 
input at the master controller.
Presets use their programmed master intensity value.