Bock Water heaters Electric Water Heaters Merkblatt

Seite von 2
www.bockwaterheaters.com 
110 South Dickinson Street , Madison, Wisconsin 53703 
Toll Free 800.794.2491
Phone 608.257.2225
Fax 608.257.5304
80031 Rev 3/08
Dielectric Fittings:  Factory Installed
T&P Valve:  Factory Installed
Brass Drain Valve:  Factory Installed
Relief Valve Opening: 3/4”
Hand-hole Cleanout Opening:  Standard
Pressures (all): Working Pressure, 150 psi; 
 
           Testing Pressure, 300 psi
Warning:  Do not install on combustible flooring.  
Installation should be in accordance with all 
national and/or local codes.  In the absence of 
local codes, refer to NFPA 31, NFPA 54  or ANSI 
Z.21.10.1.
Caution:  The recommended maximum hot water 
termperature setting for normal residential use is 
120°F.  Bock recommends a tempering valve or 
anti-scald valve be installed and used according to 
the manufacturer’s directions to prevent scalding.
Energy Saver
120
80
50
Dimensions and Capacities
Model
Storage 
(gal)
kW 
Input
Inlet 
Pipe 
Dia.
Dimensions
Shipping Weight 
(lbs)
A
B
C
D
E
Standard
ASME
50F-*
50
**
1-1/2
24
47-3/4
46-1/2
49-1/4
41
270
302
80F-*
80
**
1-1/2
26
60-1/4
46-1/2
61-3/4
52-1/2
335
378
120F-*
119
**
1-1/2
30-1/4
64-1/2
50-1/4
66
55
430
485
*When order surface mounted thermostat, add the letter “S” before the “F”. Example 50SF 
*When ordering the Immersion thermostat add the letter “C” before the “F”. Exampe 50CF 
*For ASME construction add an “A” to the model number. Example 50CF-A 
**Add a “6”, “9”, “12”, “13.5”, “15”, “18”, “24”, “27”, “30”, “36”, “45”, or “54” to the model number to indicate kW 
    input desired.  Example 50S(C)F-6
Where Applicable
Operating Characteristics
Recovery 
@
Full Load Current Amperes (Fused Models)***
kW 
Input
208 Volts 
Phase
240 Volts 
Phase
277 
Volts 
Phase
380 
Volts 
Phase
415 
Volts 
Phase
480 Volts 
Phase
600 
Volts 
Phase
90°F 
Rise
100°F 
Rise
1
3
1
3
1
3
3
1
3
3
6
28
25
28.8
16.6
25
14.4
21.6
10
9
12.5
7.2
5.8
9
42
37
43.2
25
37.2
21.6
32.4
14
13
18.7
10.8
8.7
12
55
50
57.6
33.3
50
28.9
43.3
19
17
25
14.4
11.5
13.5
62
56
64.9
37.5
56.2
32.5
48.7
21
19
28.1
16.2
13
15
69
62
72.1
41.6
62.5
36.1
54.1
23
21
31.2
18
14.4
18
83
74
86.5
50
75
43.4
64
28
25
37.5
21.6
17.3
24
110
99
115.4
66.7
100
57.8
86.6
37
34
50
28.9
23.1
27
124
112
129.8
75
112.5
65
97.4
41
38
56.2
32.5
26
30
138
124
144.2
83.3
125
72.2
108.3
46
42
62.5
36.1
28.9
36
165
149
173
100
150
86.7
129.9
55
50
75
43.3
34.6
45
207
186
216.3
125
187.5
108.3
162.4
69
63
93.7
54.1
43.3
54
248
223
259.6
150
225
130
194.9
83
75
112.5
65
52
Number of Elements (Fused Models)***
kW 
Input
208 Volts 
Phase
240 Volts 
Phase
277 
Volts 
Phase
380 
Volts 
Phase
415 
Volts 
Phase
480 Volts 
Phase
600 
Volts 
Phase
1
3
1
3
1
3
3
1
3
3
6
3(2)
3
3(2)
3
3
3
3
3(2)
3
3
9
3
3
3
3
3
3
3
3
3
3
12
3
3
3(2)
3
3
3
3
3(2)
3
3
13.5
3
3
3
3
3
3
3
3
3
3
15
3
3
3
3
3
3
3
3
3
3
18
3
3
3
3
3
3
3
3
3
3
24
4
6
4
6
4
6
6
4
6
6
27
6
6
6
6
6
6
6
6
6
6
30
6
6
6
6
6
6
6
6
6
6
36
6
6
6
6
6
6
6
6
6
6
45
9
9
9
9
9
9
9
9
9
9
54
9
9
9
9
9
9
9
9
9
9
Units with amperage draw of 48 amps or more require factory installed internal fusing. 
***If the number of elements on non-fused models is different, it is indicated in parentheses (), following the AMP draw.