INSTALLATION 
See Pipe Manufacturers Instructions For Installation Requirements Of Venting Components And Vent Clearances. 
 
PAGE 12 
RESIDENTIAL STANDARD 
Using 6” (152 mm) Diameter Single Wall  
Connector Pipe. Not Approved For  
Manufactured (Mobile) Homes. 
 
 
MANUFACTURED (MOBILE) HOME STANDARD 
Using 6” (152 mm) Diameter Type L-Vent Connector Pipe 
 
 
 
 
IMPORTANT NOTES: 
•  Minimize the use of elbows (30°, 45° or 90°) - Offsets in the 
venting system are very restrictive and will inhibit the draft 
(i.e. You will lose approximately 5 feet of effective draft for 
every 90 degrees of direction change). This appliance re-
quires 12 to 15 feet of effective draft for optimum perform-
ance (see Draft Requirements
 on page 11). 
 
• 
First section of pipe must be vertical - Use as much straight 
vertical pipe directly above the appliance as possible be-
fore using an elbow (a 2’ to 3’ initial vertical rise is sug-
gested).
 
Chimney  
Termination Cap
 
Storm 
Collar
 
Roof 
Flashing
 
Ceiling Support
Assembly 
Slip Adapter 
Chimney 
Connector 
6” x 24” 
24-Gage 
Single Wall Pipe 
5 ¼” (134 mm)  
Floor  
Protection 
Square, Outside 
Air Floor Duct  
7 ft. (214 cm) 
Minimum
 
DVL Close  
Clearance 
Connector
 
Support Box
Minimum 12-
15 ft. (366-
458 cm) of 
Flue to 
Achieve a 
Stable Draft
 
14.5” 
(369 mm)
 
3 ft. (915 mm) 
Minimum
 
Spark Arrestor Cap
Storm Collar 
Flashing