Installation Instructions

CONNECTING DRYER USING 3-WIRE 
CONNECTION
3-wire Connection
Not for use in Canada.
DO NOT use for Mobile Home Installations.
NOT for use on new construction.
NOT for use on recreational vehicles.
NOT for use in areas where local codes prohibit grounding 
through the neutral conduction.
1.  7XUQ RȺ WKH FLUFXLW EUHDNHU V    DPS  RU UHPRYH WKH
dryer’s circuit fuse at the electrical box.
2.  Be sure the dryer cord is unplugged from the wall.
  5HPRYHWKHSRZHUFRUGFRYHUORFDWHGDWWKHORZHUEDFN
4.  ,QVWDOOLQ8/UHFRJQL]HGVWUDLQUHOLHIWRSRZHUFRUG
entry hole. Bring power cord through strain relief.
5. Connect power cord as follows:
 
A.  Connect the 2 hot lines to the outer screws of 
the terminal block (marked L1 and L2).
 
B.  Connect the neutral (white) line to the center of 
the terminal block (marked N).
6.  Be sure ground strap is connected to neutral (center)
terminal of block and to green ground screw on cabinet 
UHDU7LJKWHQDOOWHUPLQDOEORFNVFUHZV  VHFXUHO\
7.  Properly secure power cord to strain relief.
8.  5HLQVWDOOWKHFRYHU
3
 EXHAUST INFORMATION
     WARNING -
 IN CANADA AND IN THE 
UNITED STATES, THE REQUIRED EXHAUST 
DUCT DIAMETER IS 4 IN (102mm). DO NOT 
USE DUCT LONGER THAN SPECIFIED IN THE 
EXHAUST LENGTH TABLE.
8VLQJH[KDXVWORQJHUWKDQVSHFL¿HGOHQJWKZLOO
• Increase the drying times and the energy cost.
‡5HGXFHWKHGU\HUOLIH
‡$FFXPXODWHOLQWFUHDWLQJDSRWHQWLDO¿UHKD]DUG
The correct exhaust installation is YOUR 
RESPONSIBILITY. Problems due to incorrect installation 
are not covered by the warranty.
5HPRYHDQGGLVFDUGH[LVWLQJSODVWLFRUPHWDOIRLOWUDQVLWLRQ
duct and replace with UL listed transition duct.
The MAXIMUM ALLOWABLE duct length and number of 
bends of the exhaust system depends upon the type of 
duct, number of turns, the type of exhaust hood (wall cap), 
and all conditions noted below. The maximum duct length 
for rigid metal duct is shown in the table below.
EXHAUST LENGTH
4" DIA.
4"
4" DIA.
4" DIA.
2-1/2"
RECOMMENDED MAXIMUM LENGTH
Exhaust Hood Types
Recommended
No. of 90º
Elb ows
Rigid
Metal
Rigid
Metal
90 F eet
60 F eet
45 F eet
35 F eet
25 F eet
0
1
2
3
4
60 F eet
45 F eet
35 F eet
25 F eet
15 F eet
Use only  for sho rt
run installations
EXHAUST SYSTEM CHECK LIST
HOOD OR WALL CAP
• Terminate in a manner to prevent back drafts or entry of 
birds or other wildlife.
• Termination should present minimal resistance to the 
H[KDXVWDLUÀRZDQGVKRXOGUHTXLUHOLWWOHRUQRPDLQWHQDQFH
to prevent clogging.
•  Never install a screen in or over the exhaust duct. This could 
cause lint build up.
• Wall caps must be installed at least 12 in. above ground 
level or any other obstruction with the opening pointed 
down.
SEPARATION OF TURNS
For best performance, separate all turns by at least 4 ft. 
of straight duct, including distance between last turn and 
exhaust hood.
TURNS OTHER THAN 90º
• One turn of 45º or less may be ignored.
• Two 45º turns should be treated as one 90º turn.
• Each turn over 45º should be treated as one 90º turn.
• For every extra 90° elbow, reduce the allowable vent system 
length by 10 ft.
• Two 45° elbows will be treated like one 90° elbow.
• For the side exhaust installations, add one 90° elbow to the 
chart. 
• The total vent system length includes all the straight portions 
and elbows of the system (transition duct included).
WARNING: 
NEVER LEAVE THE 
COVER OFF OF THE TERMINAL BLOCK.
Screws 
(2)
Hot 
Wire
µ8/ 
5HFRJQL]HG
6WUDLQ5HOLHI
$:*PLQLPXPFRSSHUFRQGXFWRUVRU9$SRZHUVXSSO\
cord kit marked for use with dryers and provided with closed loop or 
spade terminals with upturned ends (not supplied).
Fuse
Hot 
Wire
Neutral 
(white)
Strain 
5HOLHI
Bracket
Cover
Screw
If required, by local code, install external ground (not provided) to 
grounded metal, cold water pipe, or other established ground determined 
by a qualified electrician.  
Green Ground Screw 
& Ground Strap