Creating and modifying global configuration templates
121
Model 1001MC Operations Guide 
6 • Model 1095RC management
– normal(3)
9. Configure the Remote Framing Mode pop-up menu using the following choices:
– slotted(0)
– normal(3)
10. When you have finished setting the configuration, click on the 
Submit
 button to save the changes.
Note
If you receive an invalid configuration error after creating a configura-
tion, it is resulting from an illegal combination of variables. Refer to sec-
tion 
information.
 on page 125 to activate the template.
Modifying a template
This section describes how to modify a global configuration template. The Patton Model 1095 enables the 
Model 1001MC system administrator to configure the units for a wide variety of applications. Due to the 
many different applications that are supported, care must be taken when setting the configuration of your 
modems. There are several illegal combinations of variables that could cause problems with the modems if 
implemented incorrectly. Be sure to read the following information before creating a template:
Configuration rules—Things to keep in mind when creating a template (see section 
Notes on clock mode settings (see section 
Notes on framing mode settings (see section 
Illegal configuration messages (see section 
After reviewing the rules and notes, go to section 
how to modify a template.
Configuration rules
Keep in mind the following when modifying a template:
If you have an IM2RC/K G.703/G.704 Rear Card installed with a 1095RC in your rack, the unit must 
have the Local Clock Mode set to external and the Framing Mode set to slotted
If you have an IM1/K G.703/G.704 Quick Connect Module installed with your 1095 at the remote site, 
the units must have the Clock Mode set to external-external and the Framing Mode for both the local and 
remote units must be set to slotted
If you have any other interface connected to your 1095RC or your 1095 modems, the Framing Mode must 
be set to normal
The system administrator should only set the Clock Mode to external-external(4) if there is an IM2RC/K 
installed in the 1095RC at the rack and an IM1/K installed in the 1095 standalone unit at the remote site. 
When setting a unit for the external clock mode, the unit must have an external clock source in order to make 
a link. When using either an IM2RC/K or an IM1/K, the K module will always provide the external clock for