Model 2707RC Configuration—Configuration page MIB variables description
183
Model 1001MC Operations Guide 
8 • Model 2707RC management
Loop Time Out (loopTo)
This displays the amount of time that the unit responding to a Remote Loop command will remain in test 
mode when the RL test mode is invoked. If the unit is not taken out of test mode by the menu within this time 
period, the unit will automatically time out and return to normal data mode. The timeout does not apply for 
loops selected via the front panel switches. 
TM from DTE (testModeDTE)
This displays if the 2707RC responds to the LL and RDL signals coming from the DTE.
Configuration Type (configType)
This displays if the 2707RC is using the DIP switch control or software control for its configuration.
Software Version (softVersion2707RC)
This displays the software version of code in the 2707RC. 
Model 2707RC Configuration—Configuration page MIB 
variables description
The 
Model 2707RC Configuration—Configuration
 page enables you to update the configuration of the 
2707RC NetLink-E1 NTU modems that are installed in the system. After making changes to the configuration 
on this page, select Back to return to the 
Model 2707RC Configuration Slot
 page, then select onLine as the 
Input Mode, and finally, select 
Submit Query
 to send the new information to the Model 1001MC over the net-
work. 
Note
If the NetLink-E1 NTU modems are not connected, and changes 
made to the remote configuration will be lost after the units link-up. 
All parameters in the Local column can be changed at any time. 
The following sections describes the MIB variables that are available on the 
Model 2707RC Configuration—
Configuration
 page. 
Line Status (lineStatus2707RC)
This variable displays the status of the line. There are three possible values that can be displayed: 
lineDown(1)
dataMode(2)—When the line status is dataMode(2), the units are linked-up and ready to send data
testMode(3) 
Software Version (softVersion2707RC)
This read-only MIB variable displays the current version of code that is running in the NetLink-E1 rack 
card modem. 
Configuration Type (configType)
This displays if the 2707RC is using the DIP switch control or software control for its configuration.