Patton electronic 1001MC Benutzerhandbuch

Seite von 288
Introduction
277
Model 1001MC Operations Guide 
11 • Troubleshooting and maintenance
Introduction
This chapter describes troubleshooting and fault analysis that can be performed by the operator. This section 
contains the following sections to help you troubleshoot the 1001MC rack card and NetLink rack cards:
Troubleshooting the 100MC rack card (see 
Troubleshooting network malfunctions (see 
Running test mode diagnostics (see 
Replacing a 1001MC rack card (see 
)
If you require more help, refer to chapter 12,
Troubleshooting the 1001MC rack card
common symptoms and suggested remedies.
Note
The following information assumes that there is only one failure involv-
ing the Model 1001MC and that if you perform the corrective action 
listed, it will solve the problem. If you are unable to correct a failure, 
refer to chapter 12,
Note
When replacing the 1001MC, follow the procedures cited in section 
Table 15. LED indicators
LED
Color
Function
Description
 Power
Green Power status
On = Power is ON
Off = Power is OFF
 LI
Green Ethernet: Twisted-
pair link indication
On = Connected to active LAN
Off = Not connected to active LAN
TD
Yellow/
Green
Ethernet: Transmit 
data from 1001MC 
to LAN
Yellow = Idle condition
Green = Toggles yellow/green 
with activity
RD
Yellow/
Green
Ethernet: Receive 
data at 1001MC 
from LAN
Yellow = Idle condition
Green = Toggles yellow/green 
with activity
 Poll
Yellow Heartbeat 
indicator
Toggles when packet TX is on the 
backplane bus
Fault
Red
Fault condition
On = Signals hardware fault
Off = No hardware fault