Using the Download page to upgrade 1094ARC software
87
Model 1001MC Operations Guide 
5 • Model 1094ARC management
Remote Circuit ID (remoteCircuitID)
The circuit ID is a 40-byte string that is stored in non-volatile flash within the Model 1001MC.
Alarm Information
Clear Slot Alarms (resetStatus)
Selecting this push button erases the alarms (errors and warning) associated with the specified slot. 
Note
The errors and warning will still be listed in the System Log.
Hardware Reset (resetStatus)
Selecting this push button will force the associated modem to perform a hardware reset. 
Card Lost Indication (cardLostIndication)
This variable allows you to choose what type of indication will be made if a modem is removed from the man-
agement system. Three choices are available:
Error
Warning
None
Line Down Indication (lineDownIndication)
This variable allows you to choose what type of indication will be made if a modem reports a line down sce-
nario. Three choices are available:
Error
Warning
None
Note
Line Down Indication
 must be set to error(2) line up and line down 
SNMP trap messages to be sent.
Using the Download page to upgrade 1094ARC software
Do the following to download new software into your NetLink modem:
1. Remove the card that you wish to upgrade from the rack chassis.
2. Make a note of the settings of DIP switches S2-6 and S2-7.
3. Set DIP switches S2-6 and S2-7 to the OFF position.