To the Installer
131212
Section 1
To the Installer
The following information has been included in the
manual as safety and regulatory guidelines. For
complete installation instructions, please see the
Installation Checklist.
Installer Safety
In all areas of the world, equipment should be
installed in accordance with existing local codes.
Please contact your local authorities if you have any
questions.
Care should be taken to ensure that all basic safety
practices are followed during the installation and
servicing activities related to the installation and
service of Taylor® equipment.
S
Only authorized Taylor service personnel
should perform installation, maintenance,
and repairs on Taylor equipment.
S
Authorized service personnel should consult
OSHA Standard 29CFRI910.147 or the
applicable code of the local area for the
industry standards on lockout/tagout
procedures before beginning any installation
or repairs.
S
Authorized service personnel must ensure
that the proper protective equipment (PPE)
is available and worn when required during
installation and service.
S
Authorized service personnel must remove
all metal jewelry, rings, and watches before
working on electrical equipment.
The main power supply(s) to the unit must be
disconnected prior to performing any installation,
maintenance, or repairs. Failure to follow this
instruction may result in personal injury or death from
electrical shock or hazardous moving parts as well as
poor performance or damage to the unit.
This unit has many sharp edges that can
cause severe injuries.
Site Preparation
Review the area where the unit will be installed. Make
sure that all possible hazards to the installer, user, and
the unit have been addressed.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of
70°-75°F (21°-24°C). The unit has successfully
performed in high ambient temperatures of up to
104°F (40°C) at reduced capacities.
This unit must NOT be installed in an area
where a water jet or hose can be used. NEVER use a
water jet or hose to rinse or clean the unit. Failure to
follow this instruction may result in electrocution.
This unit must be installed on a level surface
to avoid the hazard of tipping. Extreme care should be
taken in moving this unit for any reason. Two or more
persons are required to safely move this unit. Failure
to comply may result in personal injury or damage to
the unit.
The authorized installer should inspect the unit for
damage and promptly report any damage to the local
authorized Taylor distributor.
This unit is made using USA sizes of hardware. All
metric conversions are approximate and vary in size.
Air Cooled Units
DO NOT obstruct air intake and discharge openings:
Air cooled units require a minimum of 3” (76 mm) of
clearance around all sides of the freezer and 12” (305
mm) of clearance on top, to allow for adequate air flow
across the condensers. Failure to allow adequate
clearance can reduce the refrigeration capacity of the
freezer and possibly cause permanent damage to the
compressor.