KitchenAid Electric Built-In Microwave/Oven Combination Benutzerhandbuch

Seite von 20
6
4-Wire Cable from Home Power Supply
IMPORTANT: Use the 4-wire cable from home power supply in 
the U.S. where local codes do not allow grounding through 
neutral, New Branch circuit installations (1996 NEC), mobile 
homes and recreational vehicles, new construction and in 
Canada.
1. Connect the 2 black wires (B) together using a UL listed wire 
connector.
2. Connect the 2 red wires (C) together using a UL listed wire 
connector.
3. Untwist white wire from green (or bare) ground wire coming 
from the oven.
4. Connect the 2 white wires (F) together using a UL listed wire 
connector. 
5. Connect the green (or bare) ground wire (H) from the oven 
cable to the green (or bare) ground wire (in the junction box) 
using a UL listed wire connector.
6. Install junction box cover.
3-Wire Cable from Home Power Supply - U.S. Only
IMPORTANT: Use the 3-wire cable from home power supply 
where local codes permit a 3-wire connection.
1. Connect the 2 black wires (C) together using a UL listed wire 
connector.
2. Connect the 2 white wires (D) and the green (or bare) ground 
wire (of the oven cable) using a UL listed wire connector.
3. Connect the 2 red wires (G) together using a UL listed wire 
connector.
4. Install junction box cover.
Install Water Filtration System
Install Water Filter 
1. Install the water filter near the cold water supply pipe under 
the kitchen sink to filter the cold water.
IMPORTANT: Be sure to allow a minimum clearance of 
1½" (3.8 cm) under the filter system for removing the filter 
cartridge.
Typical Installation Configuration
NOTE: For unique installations contact a licensed plumber.
2. Attach the supplied water filter mounting ring and screw at 
the recommended location.
3. Attach filter to the mounting ring.
Connect to Home Water Supply
1. Make connection to the cold water supply line. 
A leak-tight connection to the ¼" copper tubing must be 
provided. 
Check local codes for type of connection required.
Copper water supply tubing must be cut with a copper tubing 
cutter so the ends are concentric and without burrs.
NOTE: It is recommended that the cold water line be soft water.
A. Cable from home power supply
B. Black wires
C. Red wires
D. 4-wire flexible conduit from 
oven
E. Junction box
F. White wires
G. UL listed wire connectors
H. Green (or bare) ground wires
I. UL listed or CSA approved 
conduit connector
A. Cable from home power supply
B. Junction box
C. Black wires
D. White wires
E. Green (or bare) ground wire 
(from oven)
F. 4-wire flexible conduit from 
oven
G. Red wires
H. UL listed wire connectors
I. UL listed or CSA approved 
conduit connector
A
B
C
D
E
F
G
H
I
B
C
D
E
F
H
G
A
I
Filter
Assembly
Cold  water
supply
Hot Cold
Water supply
line to cold
water supply
Water supply
line to oven
Mounting ring and screw
1½" (3.8 cm) clearance