Location:
  On Early VP17 Models the tank heater switch is 
located on the rear of the brewer on the upper left side 
of the trunk.
 
On VP17B Models the tank heater switch is located 
on left side of the control panel.
Test Procedure:
1.  Disconnect the brewer from the power source.
2.  Disconnect the black wire from the limit thermo-
stat.
3.  With a voltmeter, and with the tank heater switch in 
the "ON" (upper) position check the voltage between 
the black wire removed from the limit thermostat 
and the white wire on the tank heater. Connect the 
brewer to the power source. The indication must 
be:
 
a) 100 volts ac on two wire 100 volt models.
 
b) 120 volts ac on two wire 120 volt models.
4.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #5.
If voltage is not present as described, refer to the Wiring 
Diagrams and check the brewer wiring harness.
5.  Check for continuity between the black wire re-
moved from the limit thermostat and the black insert 
on the terminal block, with the tank heater  switch 
in the "ON" (upper) position. Continuity should not 
be present in the "OFF" (lower) position.
If continuity is present as described, the tank heater 
switch is operating properly.
If continuity is not present as described, replace the 
tank heater switch.
Removal and Replacement: (VP17)
1.  Remove the tank inlet fitting securing fill basin to 
the tank lid. Remove fill basin and gasket. Set all 
three parts aside for reassembly.
2.  Remove sprayhead and hex nut securing sprayhead 
tube to the hood. Set aside for reassembly.
3.  Disconnect the wires on the limit thermostat and 
the tank heater.
4.  Gently pull the thermostat sensor and grommet 
from the tank lid.
5.  Insert a tube to the bottom of the tank and syphon 
ALL of the water out. 
6.  Gently reinstall the thermostat sensor and grom-
met in the tank lid.
7.  Remove the two #8-32 screws securing the tank 
assembly to the hood.
8.  Lift tank and components out as an assembly and 
set aside for reassembly.
9.  Disconnect the two black wires from the tank heater 
switch.
10. Remove the plastic facenut, hex facenut and the 
switch indicator/guard bracket that secures tank 
heater switch to the brewer. Remove switch and 
discard.
11. Insert new tank heater switch through the hole in 
the upper left rear of the trunk and secure with
  switch indicator/guard bracket, hex facenut and 
plastic facenut.
12. Reconnect the two black wires the tank heater 
switch terminals.
TANK HEATER SWITCH (VP17B and early model 
VP17)
P1161.40
VP17 MODELS (Early Models)
VP17B MODELS
P1319.40
SERVICE (cont.)
FIG. 10 TANK HEATER SWITCH
46721  052512