5. TROUBLESHOOTING 
5.1 Troubleshooting 
The following guide lists the most common problems that may be encountered when 
operating this bar code printer. If the printer still does not function after all suggested 
solutions have been invoked, please contact the Customer Service Department of 
your purchased reseller or distributor for assistance.   
 
Phenomenon 
Cause of Errors 
Recovery Procedure 
No ribbon 
1.  Running out of ribbon 
2.  The ribbon is installed 
incorrectly. 
3.  The ribbon sensor is not 
been well calibrated. 
1.  Supply a new ribbon roll. 
2.  Please refer to the steps in 
user’s manual to reinstall 
the ribbon. 
3.  Please calibrate the ribbon 
sensor 
No paper 
1.  Running out of label 
2.  The label is installed 
incorrectly. 
3.  The moveable gap/black 
mark sensor is not placed 
in the proper location. 
1.  Supply a new label roll. 
2.  Please refer to the steps in 
user’s manual to reinstall 
the label roll. 
3.  Please move the sensor to 
the proper location. 
Poor printing quality 
1.  Dirt is accumulated on the 
print head. 
2.  The density setting is not 
set properly 
3.  Ribbon and media are 
incompatible. 
4.  The pressure of print head 
is not set properly 
1.  Please refer to the steps in 
us
er’s manual to clear the 
print head. 
2.  Adjust the print density and 
speed. 
3.  Change proper ribbon or 
proper label roll. 
4.  Adjust the print head 
pressure adjustment knob. 
Power indicator does 
not illuminate 
1. The power cord is not 
properly connected. 
2. The voltage setting of 
power supply in the rear of 
printer is set incorrectly. 
1.  Please check whether the 
power cord is well 
connected between printer 
and outlet. 
2.  Please set the voltage 
setting of power supply at 
the rear of printer to the 
proper voltage. 
Paper jam 
1.  The label size is not set 
properly. 
1.  a. Reset the label size. 
b. Re-calibrate the