Spinpoint M8U-Internal Product Manual REV 3.4 
46 
INSTALLATION 
 
 
 
Power  switching  on  any  non-removable  function  may  be  implemented  either  by  removing  its  power  or  by 
shutting  off the clock.  Switching  on the non-removable  function  is not required  if the aggregate  power  drawn 
by  it and  the  Hub  Controller  is  less  than  one  unit  load.  However,  as  long  as the  hub  port  associated  with  the 
function  is  in  the  Power-off  state,  the  function  must  be  logically  reset  and  the  device  must  appear  to  be  not 
connected.  The  total  current  drawn  by  a bus-powered  device  is the  sum of the  current  to the  Hub  Controller, 
any non-removable  function(s),  and the downstream  facing ports. 
Figure  6-12  shows  the  partitioning  of power  based  upon  the  maximum  current  draw  (from  upstream)  of five 
unit loads: one unit load for the Hub Controller  and the non-removable  function  and one unit load for each of 
the external  downstream  facing  ports.  If more  than  four  external  ports  are required,  then  the hub  will need  to 
be self-powered.  If the non-removable  function(s)  and Hub Controller  draw  more than one unit load, then the 
number  of  external  ports  must  be  appropriately  reduced.  Power  control  to  a  bus-powered  hub  may  require  a 
regulator.  If  present,  the  regulator  is  always  enabled  to  supply  the  Hub  Controller.  The  regulator  can  also 
power  the  non-removable  functions(s).  Inrush  current  limiting  must  also  be  incorporated  into  the  regulator 
subsystem. 
 
 
 
 
Figure 6-12: Compound  Bus-powered  Hub 
 
Power  to  external  downstream  facing  ports  of  a  bus-powered  hub  must  be  switched.  The  Hub  Controller 
supplies  a  software  controlled  on/off  signal  from  the  host,  which  is  in  the  “off”  state  when  the  device  is 
powered  up  or  after  reset  signaling.  When  switched  to  the  “on”  state,  the  switch  implements  a  soft  turn-on 
function  that  prevents  excessive  transient  current  from  being  drawn  from  upstream.  The  voltage  drop  across 
the upstream  cable, connectors,  and switch  in a bus-powered  hub  must not exceed  350  mV at maximum  rated 
current. 
 
 
 
 
 
 
6.2.3.3  
Self-powered Hubs 
Self-powered  hubs  have  a local  power  supply  that  furnishes  power  to any non-removable  functions  and to all 
downstream  facing  ports,  as  shown  in  Figure  6-13.  Power  for  the  Hub  Controller,  however,  may  be  supplied 
from the upstream  V
BUS 
(a “hybrid”  powered  hub) or the local power supply.  The advantage  of supplying  the 
Hub Controller  from the upstream  supply  is that communication  from the host is possible  even if the device’s 
power  supply  remains  off.  This  makes  it  possible  to  differentiate  between  a  disconnected  and  an  unpowered 
device.  If  the  hub  draws  power  for  its  upstream  facing  port  from  V
BUS
,  it  may  not  draw  more  than  one  unit 
load. 
The  number  of ports  that  can  be supported  is  limited  only  by  the  address  capability  of the  hub  and  the  local 
supply.  Self-powered  hubs  may  experience  loss of power.  This  may  be the result  of disconnecting  the power 
cord or exhausting  the battery.  Under  these conditions,  the hub may  force a re-enumeration  of itself as a bus- 
powered  hub.  This  requires  the  hub to implement  port power  switching  on all external  ports.  When  power  is 
lost,  the  hub  must  ensure  that  upstream  current  does  not  exceed  low-power.  All  the  rules  of  a  bus-powered 
hub then apply.