Samsung ST750LM024 Benutzerhandbuch

Seite von 111
Spinpoint M8U-Internal Product Manual REV 3.4 
50 
INSTALLATION 
 
 
 
The  function  address  (ADDR)  field  specifies  the  function,  via  its  address,  that  is  either  the  source  or 
destination  of a data packet, depending  on the value of the token PID. As shown in Figure 6-15, a total of 
128 addresses  are specified  as ADDR<6:0>.  The ADDR  field is specified  for IN, SETUP,  and OUT tokens 
and  the  PING  and  SPLIT  special  token.  By  definition,  each  ADDR  value  defines  a  single  function.  Upon 
reset  and  power-up,  a  function’s  address  defaults  to  a  value  of  zero  and  must  be  programmed  by  the  host 
during  the  enumeration  process.  Function  address  zero  is  reserved  as  the  default  address  and  may  not  be 
assigned to any other use. 
 
 
 
Figure 6-15: ADDR Field 
 
6.3.2.4  
Endpoint Fields 
An  additional  four-bit  endpoint  (ENDP)  field,  shown  in  Figure  6-16,  permits  more  flexible  addressing  of 
functions  in which  more than one endpoint  is required.  Except  for endpoint  address  zero, endpoint  numbers 
are  function-specific.  The  endpoint  field  is  defined  for  IN,  SETUP,  and  OUT  tokens  and  the  PING  special 
token.  All  functions  must  support  a  control  pipe  at  endpoint  number  zero  (the  Default  Control  Pipe).  Low 
speed  devices  support  a  maximum  of three  pipes  per  function:  a control  pipe  at endpoint  number  zero  plus 
two  additional  pipes  (either  two  control  pipes,  a  control  pipe  and  an  interrupt  endpoint,  or  two  interrupt 
endpoints).  Full-speed  and  high-speed  functions  may  support  up  to  a  maximum  of  16  IN  and  OUT 
endpoints. 
 
 
Figure 6-16: Endpoint  Field 
 
6.3.2.5  
Frame Number Fields 
The frame  number  field is an 11-bit field that is incremented  by the host on a per-frame  basis.  The frame 
number  field rolls over  upon reaching  its maximum  value  of 7FFH  and is sent only  in SOF tokens  at the 
start of each (micro) frame. 
 
 
6.3.2.6  
Data Fields 
The data field may  range  from zero to 1,024 bytes and must be an integral  number  of bytes.  Figure  6-17 
shows the format for multiple bytes. Data bits within each byte are shifted out LSb first. 
 
 
 
Figure 6-17: Data Field Format 
 
6.3.2.7  
Cyclic Redundancy Checks 
Cyclic  redundancy  checks  (CRCs)  are  used  to  protect  all  non-PID  fields  in  token  and  data  packets.  In  this 
context,  these  fields  are  considered  to  be  protected  fields.  The  PID  is  not  included  in  the  CRC  check  of  a 
packet  containing  a  CRC.  All  CRCs  are  generated  over  their  respective  fields  in  the  transmitter  before  bit 
stuffing  is  performed.  Similarly,  CRCs  are  decoded  in  the  receiver  after  stuffed  bits  have  been  removed. 
Token  and  data  packet  CRCs  provide  100%  coverage  for all single-  and double-bit  errors.  A failed  CRC  is 
considered  to indicate  that one or more of the protected  fields is corrupted  and causes  the receiver  to ignore 
those fields and, in most cases, the entire packet. 
For CRC generation  and checking,  the shift registers in the generator  and checker are seeded with an allones 
pattern. For each data bit sent or received,  the high order bit of the current remainder  is XORed with