Horizontal Termination
„
Wall Cut-out Opening: A minimum 10" X 10" (250 mm x
250 mm) square hole is required for proper pipe clear-
ances through a combustible wall.  Use vent
manufacturer’s WALL THIMBLE for the wall penetration.
DO NOT FILL AIR SPACE WITH ANY TYPE OF INSULATION.
„
The minimum horizontal run made directly off the
rear of the stove into a standard horizontal cap  shall
be no less than a 6” vent section.  See fig. 8.
„
The maximum horizontal run made directly off the
rear of the stove into a standard horizontal cap (#984
or #985) must include no more than a 12” and 6”
section of Simpson Dura-Vent pipe installed together.
See fig.9.
„
The maximum horizontal run made directly off the
rear of the stove into a 14” snorkel cap  must include
no more than a 24” vent section .  See fig. 10.
„
The horizontal termination cap must maintain a 3"
clearance to any overhead combustible projections
2 1/2" or less.  It must also maintain 12" clearance
from projections exceeding 2 1/2".   See fig. 14.
„
Any horizontal run of vent must be level or have a
1/4" rise for every foot of run toward the termination
cap. NEVER ALLOW THE VENTING TO RUN DOWN-
WARD FROM STOVE TO TERMINATION; DOWNWARD
VENT RUNS TRAP HEAT AND CAUSE HIGH TEMPERA-
TURES TO DEVELOP WITHIN THE VENT THAT COULD
START A FIRE.
„
Install a Vinyl Siding Standoff between the vent
termination and an exterior wall covered by vinyl
siding material to prevent potential heat damage to
the siding.
„
Do not recess the termination cap into a wall or
siding.
Options for immediate horizontal venting
directly off the rear of the stove
Figure 8.  Minimum Horizontal Run - Standard Termination.
Standard Horizontal
Termination Cap
Min. Horizontal: 6”
No draft restriction required.
  5” min.
130 mm
WALL THIMBLE required.
12
12
12
12
12
12
12
12
12
12
Standard Horizontal
Termination Cap
Max. Horizontal Run:
12”
No draft restriction required.
17” Max.
430 mm
WALL THIMBLE  required.
12
12
12
12
12
12
12
12
12
12
Figure 9.  Maximum Horizontal Run - Standard
Termination.
 WALL THIMBLE  required.
14” Snorkel
Figure 10.  Maximum Horizontal Run with Snorkel
Termination.
12
12
12
12
12
12
Max. Horizontal run into a 14”
snorkel:  24”
A draft restrictor is required.
24 3/4”
(630 mm)