Hearth & Home Technologies MBK Benutzerhandbuch

Seite von 32
R
Page 6
   7004-187F  September 1, 2008
Yosemite Wood Stove
B
A
C1
Non-fuel 
door side
D2
Fuel Door 
side
C2
D1
CLEARANCES TO COMBUSTIBLES (UL and ULC)
G
H
E1
E2
F1
F2
Fuel door 
side
Non-fuel 
door side
G
G*
Max Mantel Depth 
10" (254mm) 
IF SIDE FUEL LOADING DOOR IS NOT USED:  
• It must remain in the locked position at all times
• Use clearances for non-fuel door side for both sides
TOP VENT VERTICAL
 
A B  
C1 C2 
D1 D2 
E1 
E2 F1 F2 G 
H
Single Wall-USA
 
12.5(316) 9(229)  19.5(495) 25.5(648) 10(254) 16 (406) 14(356) 16(406)  18.5(470) 20.5(521)  59(1499) N/A
Single Wall-Canada 
12.5(316) 9(229)  19.5(495) 27.5(699) 10(254) 18 (457) 14(356) 18(457)  18.5(470)  22.5(572)  59(1499) N/A
Double Wall-USA 
10.5(267) 7(178)  19.5(495) 25.5(648) 10(254) 16(406) 7 (178) 16(406)  11.5(292)  20.5(521)  59(1499) N/A
Double Wall-Canada  10.5(267) 7(178)  19.5(495) 27.5(699) 10(254) 18(457) 7 (178) 18(457)  11.5(292)  22.5(572)  59(1499) N/A
HORIZONTAL WITH MINIMUM 2FT (609mm) VERTICAL OFF STOVE TOP
Single Wall-USA
 
13.5(343) 10(254)  19.5(495) 25.5(648) 10(254)  16 (406)  N/A 
N/A 
N/A 
N/A 
59(1499)  18*
Single Wall-Canada 
13.5(343) 10(254)  19.5(495)  27.5(699) 10(254)  18 (457)  N/A 
N/A 
N/A 
N/A 
59(1499)  18*
Double Wall-USA 11.5(330) 
8(203) 
19.5(495) 
25.5(648) 
10(254) 
16(406) 
N/A 
N/A  N/A  N/A 59(1499) 
18*
Double Wall-Canada  11.5(330) 8(203)  19.5(495) 27.5(699) 10(254)  18(457)  N/A 
N/A 
N/A 
N/A 
59(1499)  18*
90
O
 ELBOW OFF TOP OF STOVE THROUGH BACKWALL
Single Wall-USA 
 
13.5(343) 10(254)  19.5(495)  25.5(648) 10(254)  16 (406)  N/A 
N/A 
N/A 
N/A 
59(1499)  N/A
Single Wall-Canada 
13.5(343) 10(254)  19.5(495)  27.5(699) 10(254)  18 (457)  N/A 
N/A 
N/A 
N/A 
59(1499)  N/A
Double Wall-USA 11(279) 
7.5(191) 
19.5(495) 
25.5(648) 
10(254) 
16(406) 
N/A 
N/A N/A N/A 
59(1499) 
N/A
Double Wall-Canada 11(279) 
7.5(191) 
19.5(495) 27.5(699) 
10(254) 18(457) 
N/A  N/A 
N/A 
N/A  59(1499) 
N/A
ALCOVE -
 Six inch (6") (152mm) diameter listed DOUBLE WALL air insulated connector pipe with UL103 HT listed factory-built Class "A" 
chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor.) 
Double Wall-USA 11.5(292) 
8(203) 
19.5(495) 
25.5(648) 
10(254) 
16(406) 
N/A 
N/A  N/A N/A 42(1067) 
N/A
Double Wall-Canada 11.5(292) 8(203) 19.5(495) 27.5(699) 10(254) 18(457) N/A  N/A 
N/A 
N/A  42(1067) N/A
REAR VENT INSTALLATIONS IN A MASONRY FIREPLACE OR THROUGH THE WALL:  
Six inch (6") (152mm) diameter 
listed double wall air insulated connector pipe with UL103 HT listed factory-built Class "A" chimney, or a masonry chimney.  (Mobile Home 
must be equipped with a spark arrestor). Additional specifications include a MAXIMUM 10" (254mm) MANTEL WIDTH and the following 
clearances.  Accessory Horizontal Heat Shield, Part HTSHLD-7006, is required for rear vent installations.
Double Wall-USA
 
N/A 4(102) 
19.5(495) 
25.5(658) 
10(254) 
16(406) 
N/A 
N/A  N/A  N/A 
30(762) 
ceiling  N/A
Double Wall-Canada
 
N/A 4(102) 
19.5(495) 
27.5(699) 
10(254) 
18(457) 
N/A 
N/A  N/A  N/A 
30(762) 
ceiling  N/A
 
 
 
USA or Canada - Single or Double Wall Pipe: 21(533) mantel 
*NFPA MINIMUM CLEARANCE - NOT TESTED
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS: In Inches & (Millimeters)
NOTE:  All "A" , "C" and "F" Dimensions are to the inside diameter of the flue collar.
 
Max Depth 
 
Min Width 
 
Min Height
Front Door 
48(1219) 
 
44(1118) 
 
54(1372)
Side Door-USA 
48(1219) 
 
56(1422) 
 
54(1372)
Side Door-Canada 
48(1219) 
 
60(1524) 
 
54(1372)
OMNI-Test Laboratories, Inc Safety Report Test Number:  061-S-54-2
Alcove
Vertical
Horizontal
Horizontal, then Vertical