Samsung 16-8900 Benutzerhandbuch

Seite von 75
U
SER
M
ANUAL
 
 
 
H.264
 
R
EAL 
T
IME 
DVR 
12 
1-7. RS-485 connection 
①  This  device  has  1  data  port  (RS-485).  You  can  use  this 
port to connect a PTZ camera or keyboard. (Optional) 
②  PTZ camera / keyboard connection 
i. 
Connect the PTZ serial communication cable to the 
RS-485 port. 
ii.  When connecting the cable, make sure the polarity 
is the right way around. One port is marked “+” and the other marked “-”. See your 
PTZ device manual for the correct device polarity, and attach accordingly. 
iii.  Recommended initial data setting is 9600 baud rate, 8 data bits, 1 stop bit and no 
parity. See your PTZ device manual for more information. 
iv.  When connecting the PTZ camera or keyboard, always change the setting of the DVR 
setting menu according the RS-485 setting of the camera, keyboard and this device. 
v.  If you use a PTZ camera and keyboard together, use the same baud rate for both. 
 
1-8. Control port (output) connection 
①  To  configure  the  settings  for  external  device  use  the  “Setup    Event   
Sensor/Motion/Video loss” menu. 
②  Connect your external output devices to the to the Control Output and Relay ports. 
③  Ensure you use the correct port for the devices output status. For example, connect 
Normally Open devices (NO) to an NO port, and Normally Closed (NC) devices to an NC port. 
See your output device’s manual for more information.   
1-9. Sensor (input) connection 
①  Connect one of the two leads of your sensor(s) (PIR 
sensor, magnetic sensor, etc.) to the common 
(COM) port and connect the remaining signal cable 
to the sensor number you to associate with it. 
②  Sensor type (“NC” or “NO”) can be set from   
Setup  Event  Sensor menu. 
 
Sensor 1 
Sensor 5 
Sensor 2 
Sensor 6 
Sensor 3 
Sensor 7 
Sensor 4 
Sensor 8 
Ground 
Ground 
   
Note
 
NC and NO cannot be selected simultaneously.