Section 5. Troubleshooting
5.1 
PDA Quick Troubleshooting Guide
The AquaLink RS PDA will stop communicating 
anytime interference (such as a 900 MHz device) 
prevents a valid signal transmission. When 
communication is lost the PDA Handheld Remote 
will lock on the startup screen until a good link 
is again achieved, usually within a few sec onds. 
If com mu ni ca tion is not reestablished within 
a few seconds or this happens often, use the 
troubleshooting in for ma tion in the following table 
for suggestions.
Symptom
Problem
Possible Solution
Power Center override switches 
operate when in Service or 
Time Out Mode, but the PDA 
Handheld Remote is completely 
dead (no backlight on or 
display).
Dead batteries in the PDA 
Handheld Remote.
Replace batteries.
PDA Handheld Remote 
backlight is on and the startup 
screen is displayed. The 
override switches at the power 
center operate as they should.
PDA is not communicating with 
the power center PCB.
Check the two center wires (black & yellow) of 
the four conductor cable to the transceiver 
J-box. Also check the installation of the PPD on 
the power center PCB. If the PPD is not seated 
correctly the system will not communicate.
PDA Handheld Remote 
backlight is on and the startup 
screen is displayed, but 
override switch es at the power 
center do not operate at all.
1.  Damaged or improperly 
installed PPD.
2.  Wrong PPD.
3.  Damaged power center 
PCB.
1.  Check alignment of the PPD.
2.  Make sure that the PPD is for a PDA.
3.  If PPD is installed correctly, replace the 
power center PCB.
Some buttons do not operate 
from the PDA Handheld 
Remote, nor from the power 
center override switches.
Wrong PPD chip installed at 
the power center PCB.
Ensure that the PPD revision number is the 
correct revision required for the application.
System locked up.
Microprocessor locked.
Turn off power to the system. Disconnect 
battery at the Power Center and turn on power. 
Reconnect the battery and reset time and date.
Programs do not run at the 
correct time.
AquaLink RS does not display 
correct time and date.
At the PDA Handheld Remote, set correct time 
and date. In Diagnostics, check battery level. 
If LOW BATTERY is displayed, replace battery 
at the Power Center to ensure correct time and 
date are maintained.