Pentair P4 Benutzerhandbuch
Page 30
7.3
DIP Switch Settings for
Pool or Spa Only
DIP Switch #
OFF
ON
1
AUX1= any equipment
AUX1= Pool Cleaner
2
AUX2= any equipment
AUX2= Low Speed for a two-speed filter
pump.
Filter pump circuit becomes High Speed.
pump.
Filter pump circuit becomes High Speed.
3
AUX3= any equipment
No change
4
Heater cool down operates.
Heater cool down disabled.
5
Normal operation
Factory adjustment- when this switch is on,
temperature delays are eliminated.
Do not leave this switch in the ON
position.
temperature delays are eliminated.
Do not leave this switch in the ON
position.
6
Spare
No change
7
Spare
No change
8
After thermostat setting has been reached,
heater will remain OFF for 3 minutes.
heater will remain OFF for 3 minutes.
After thermostat setting has been reached,
heater will remain OFF for 5 minutes.
heater will remain OFF for 5 minutes.