BenutzerhandbuchInhaltsverzeichnisHome1Contents3Getting Started9Before you begin11About this manual11Transmitter model code11Communications tools and protocols11Additional documentation and resources12Quick start13Power up the transmitter13Check flowmeter status13Make a startup connection to the transmitter14Characterize the flowmeter (if required)15Sample sensor tags16Flow calibration parameters (FCF, FT)17Density calibration parameters (D1, D2, K1, K2, FD, DT, TC)18Verify mass flow measurement18Verify the zero19Verify the zero using ProLink II19Terminology used with zero verification and zero calibration20Configuration and commissioning23Introduction to configuration and commissioning25Configuration flowchart25Default values and ranges26Enable access to the off-line menu of the display27Disable write-protection on the transmitter configuration27HART security27Restore the factory configuration28Configure process measurement29Configure mass flow measurement29Configure Mass Flow Measurement Unit29Options for Mass Flow Measurement Unit30Define a special measurement unit for mass flow31Configure Flow Damping32Effect of Flow Damping on volume measurement32Interaction between Flow Damping and Added Damping33Configure Mass Flow Cutoff33Effect of Mass Flow Cutoff on volume measurement33Interaction between Mass Flow Cutoff and AO Cutoff33Configure volume flow measurement for liquid applications34Configure Volume Flow Type for liquid applications35Configure Volume Flow Measurement Unit for liquid applications35Options for Volume Flow Measurement Unit for liquid applications36Define a special measurement unit for volume flow37Configure Volume Flow Cutoff38Interaction between Volume Flow Cutoff and AO Cutoff39Configure gas standard volume (GSV) flow measurement39Configure Volume Flow Type for gas applications40Configure Standard Gas Density40Configure Gas Standard Volume Flow Measurement Unit41Options for Gas Standard Volume Flow Measurement Unit41Define a special measurement unit for gas standard volume flow42Configure Gas Standard Volume Flow Cutoff44Interaction between Gas Standard Volume Flow Cutoff and AO Cutoff44Configure Flow Direction45Options for Flow Direction46Effect of Flow Direction on mA outputs46Effect of Flow Direction on frequency outputs49Effect of Flow Direction on discrete outputs49Effect of Flow Direction on digital communications49Effect of Flow Direction on flow totals50Configure density measurement50Configure Density Measurement Unit51Options for Density Measurement Unit51Configure slug flow parameters52Slug flow detection and reporting53Configure Density Damping53Effect of Density Damping on volume measurement54Interaction between Density Damping and Added Damping54Configure Density Cutoff54Effect of Density Cutoff on volume measurement55Configure temperature measurement55Configure Temperature Measurement Unit55Options for Temperature Measurement Unit56Configure Temperature Damping56Effect of Temperature Damping on process measurement57Configure the petroleum measurement application57Configure petroleum measurement using ProLink II57Configure petroleum measurement using the Field Communicator58API reference tables59Configure the concentration measurement application61Configure concentration measurement using ProLink II61Configure concentration measurement using the Field Communicator63Standard matrices for the concentration measurement application65Derived variables and calculated process variables66Configure pressure compensation68Configure pressure compensation using ProLink II68Configure pressure compensation using the Field Communicator70Options for Pressure Measurement Unit71Configure device options and preferences73Configure the transmitter display73Configure the language used for the display73Configure the process variables shown on the display74Configure Display Variable 1 to track the primary mA output75Configure the precision of variables shown on the display75Configure the refresh rate of data shown on the display76Enable or disable automatic scrolling through the display variables76Enable or disable the display backlight77Enable or disable Status LED Blinking77Enable or disable operator actions from the display77Enable or disable Totalizer Start/Stop from the display78Enable or disable Totalizer Reset from the display78Enable or disable the Acknowledge All Alarms display command79Configure security for the display menus80Configure response time parameters81Configure Update Rate81Effects of Update Rate = Special82Configure alarm handling83Configure Fault Timeout83Configure Status Alarm Severity84Status alarms and options for Status Alarm Severity85Configure informational parameters87Configure Descriptor87Configure Message87Configure Date88Configure Sensor Serial Number88Configure Sensor Material89Configure Sensor Liner Material89Configure Sensor Flange Type89Integrate the meter with the control system91Configure the mA output91Configure mA Output Process Variable92Options for mA Output Process Variable92Configure Lower Range Value (LRV) and Upper Range Value (URV)94Default values for Lower Range Value (LRV) and Upper Range Value (URV)95Configure AO Cutoff95Interaction between AO Cutoff and process variable cutoffs96Configure Added Damping97Interaction between Added Damping and process variable damping97Configure mA Output Fault Action and mA Output Fault Level98Options for mA Output Fault Action and mA Output Fault Level99Configure the frequency output99Configure Frequency Output Power Source100Configure Frequency Output Process Variable100Options for Frequency Output Process Variable101Configure Frequency Output Polarity101Options for Frequency Output Polarity101Configure Frequency Output Scaling Method102Calculate frequency from flow rate102Configure Frequency Output Maximum Pulse Width103Configure Frequency Output Fault Action and Frequency Output Fault Level104Options for Frequency Output Fault Action105Configure the discrete output105Configure Discrete Output Power Source106Configure Discrete Output Source106Options for Discrete Output Source107Configure Flow Switch parameters108Configure Discrete Output Polarity108Options for Discrete Output Polarity109Illustration of discrete output circuit110Configure Discrete Output Fault Action110Options for Discrete Output Fault Action111Fault indication with the discrete output111Configure the discrete input111Configure Discrete Input Action112Options for Discrete Input Action112Configure Discrete Input Polarity113Options for Discrete Input Polarity114Configure the mA input114Configure mA Input Process Variable115Configure Lower Range Value (LRV) and Upper Range Value (URV)115Configure events116Configure a basic event116Configure an enhanced event117Options for Enhanced Event Action118Configure digital communications119Configure HART/Bell 202 communications120Configure burst parameters121Configure HART variables (PV, SV, TV, QV)122Options for HART variables122Interaction of HART variables and transmitter outputs124Configure HART/RS-485 communications124Configure Modbus/RS-485 communications125Configure Digital Communications Fault Action127Options for Digital Communications Fault Action127Set up polling for temperature128Set up polling for pressure130Completing the configuration133Back up transmitter configuration133Enable/disable HART security133Enable write-protection on the transmitter configuration134Operations, maintenance, and troubleshooting137Transmitter operation139Record the process variables139View transmitter status using the status LED139View and acknowledge status alarms140View and acknowledge alarms using the display140View and acknowledge alarms using ProLink II143View alarms using the Field Communicator143Alarm data in transmitter memory144Read totalizer and inventory values145Start and stop totalizers and inventories145Start and stop totalizers and inventories using the display146Reset totalizers147Reset totalizers using the display147Reset inventories148Measurement support151Options for measurement support151Zero the flowmeter151Zero the flowmeter using the display152Zero the flowmeter using ProLink II153Zero the flowmeter using the Field Communicator154Validate the meter155Alternate method for calculating the meter factor for volume flow157Perform a (standard) D1 and D2 density calibration158Perform a D1 and D2 density calibration using ProLink II158Perform a D1 and D2 density calibration using the Field Communicator159Perform a D3 and D4 density calibration (T-Series sensors only)161Perform a D3 or D3 and D4 density calibration using ProLink II162Perform a D3 or D3 and D4 density calibration using the Field Communicator163Perform temperature calibration165Perform temperature calibration using ProLink II165Troubleshooting167Status LED states167Status alarms168Flow measurement problems174Density measurement problems176Temperature measurement problems177Milliamp output problems178Frequency output problems179Use sensor simulation for troubleshooting180Check power supply wiring181Check sensor-to-transmitter wiring182Check grounding182Perform loop tests182Perform loop tests using the display183Perform loop tests using ProLink II184Perform loop tests using the Field Communicator186Trim mA outputs187Trim mA outputs using ProLink II188Trim mA outputs using the Field Communicator188Check the HART communication loop189Check HART Address and Loop Current Mode190Check HART burst mode190Check Lower Range Value and Upper Range Value190Check mA Output Fault Action190Check for radio frequency interference (RFI)191Check Frequency Output Maximum Pulse Width191Check Frequency Output Scaling Method191Check Frequency Output Fault Action192Check Flow Direction192Check the cutoffs192Check for slug flow (two-phase flow)193Check the drive gain193Collect drive gain data194Check the pickoff voltage195Collect pickoff voltage data196Check for electrical shorts196Check the sensor coils196Using the transmitter display199Components of the transmitter interface199Use the optical switches201Access and use the display menu system202Enter a floating-point value using the display203Enter a floating-point value using decimal notation203Enter a floating-point value using exponential notation205Display codes for process variables206Codes and abbreviations used in display menus207Menu maps for the transmitter display210Using ProLink II with the transmitter219Basic information about ProLink II219Menu maps for ProLink II220Using the Field Communicator with the transmitter225Basic information about the Field Communicator225Menu maps for the Field Communicator226Default values and ranges237Default values and ranges237Transmitter components and installation wiring243Transmitter components243Transmitter-to-sensor wiring244Power supply terminals245Input/output (I/O) terminals246Index249Größe: 3,2 MBSeiten: 256Language: EnglishHandbuch öffnen