BenutzerhandbuchInhaltsverzeichnis1.0 Introduction91.1 Methods of Viewing and Configuring the AC891.2 Data Logs91.3 Transformer Module91.4 Available Alarms91.5 Outside Enclosure Overview10Figure 1 AC8 enclosure-external features10Figure 2 AC8 enclosure-internal features101.6 Typical Configuration11Figure 3 Typical Configuration111.7 Controller Board Overview12Table 1 Controller board components121.8 LED Indicators14Table 2 LED indicators summary141.9 Typical Sequence15Figure 4 Example of typical sequence152.0 Installation162.1 Installation Considerations162.1.1 Unpacking and Preliminary Inspection16Packing Contents16Table 3 Packing manifest162.2 Surface-Mounting the AC817Required tools172.2.1 Mounting the Panel17Figure 5 Mounting dimensions172.3 Flush-Mounting the AC818Required tools182.3.1 Mounting the Panel182.4 Connect Power to the AC8192.4.1 Termination and Mounting19Input Power Connections1924 VAC Output Power Connections20Figure 6 Power wiring to TM11520Figure 7 Power wiring to TM23020Troubleshooting - Transformer Module202.4.2 Connecting the Battery Pack20Obtaining a Replacement Battery Pack202.4.3 Turning On the AC8203.0 Wiring and Connections213.1 Wiring Specifications21Table 4 Wiring specifications213.2 Connecting Digital Inputs and Digital Outputs22Connecting Liebert Environmental Units223.2.1 Connecting Digital Inputs223.2.2 Connecting Digital Outputs233.2.3 Setting the Digital Output Jumpers23Table 5 Digital output jumper settings233.2.4 Connecting Control Relay Outputs243.2.5 Connecting the Emergency Power Operation (EPOP) Input243.2.6 Setting the EPOP Jumper243.3 Connecting Analog Inputs253.3.1 Setting the 12VDC/24VDC Analog Power Jumper253.3.2 Connecting the Analog Ground253.4 Connecting Common Alarm Outputs263.5 EIA422 SiteScan Web Connector263.6 Communications Connections263.6.1 RS232 Connector263.6.2 Phone Line Connector264.0 Overview of Menus27Table 6 Guide to AC8 functions274.1 Opening Screen Overview284.2 Main Menu Overview28Table 7 Primary functions overview284.3 LCD Menu Overview28Figure 8 LCD Menu overview285.0 View Status Options29Figure 9 Menu overview - View Status menu295.1 View Active Alarms305.1.1 Active Alarms30Viewing Additional Screens30Clearing Active Alarms305.2 View Alarm Log315.2.1 Alarm Log31Table 8 Alarm log conditions31Viewing Additional Screens315.2.2 Backing Up the Alarm Log (Service Terminal Interface only)315.3 View Event Log325.3.1 Event Log32Table 9 Event log conditions32Viewing Additional Screens325.3.2 Backing Up the Event Log (Service Terminal Interface only)325.4 View Trend Log335.4.1 Select a Sensor335.4.2 View a Trend Log33Table 10 Trend log conditions33Viewing Additional Screens335.4.3 Backing Up the Trend Log (Service Terminal Interface only)335.5 View Input Status345.5.1 Input Status34Table 11 Analog input states34Table 12 Digital input states34Viewing Additional Input Data345.6 View Output Status355.6.1 Output Status35Table 13 Digital output states35Viewing Additional Output Data355.7 View Pager Numbers365.7.1 Select a Pager365.7.2 View a Pager Number365.7.3 View a Pager PIN365.8 View Operation375.8.1 Select a Zone375.8.2 View Operation375.9 View Control Status385.9.1 Control Status386.0 Silence Alarm & Backup Log Files (Service Terminal Interface)396.1 Silence Alarm (Service Terminal Interface)396.2 Back Up Log Files (Service Terminal Interface only)407.0 System and Control Options42Table 14 Valid characters for data entry427.1 Login42Figure 10 Menu overview - System and Control menu437.2 Setup System - Overview447.3 Setup System - Setup Inputs44Table 15 Default settings - digital inputs447.3.1 Change Label (Name of Input)45Table 16 Input and output labels457.3.2 Define Input as Normally Open or Normally Closed457.3.3 Define Input as Alarmable or Event457.3.4 Set Up Alarmable Inputs in Latched or Unlatched Mode467.3.5 Set Up Delay Time467.4 Setup System - Setup Common Alarm477.5 Setup System - Setup Sensor48Table 17 Default settings - analog sensor inputs487.5.1 Identify the Sensor as Connected497.5.2 Change Sensor Label (Name)497.5.3 Change Units Label497.5.4 Change 4 mA Value507.5.5 Change 20 mA Value507.5.6 Change Offset Value507.5.7 Define Sensor as Alarmable or Event517.5.8 Set Up Alarmable Sensors in Latched or Unlatched Mode517.5.9 Change Low Setpoint527.5.10 Change High Setpoint527.5.11 Set Up Delay Time537.6 Setup System - Setup Zones547.6.1 Set Up a Zone54Table 18 Default zones547.7 Setup System - Setup Outputs55Table 19 Default settings - digital outputs557.7.1 Define Output as Normally Open or Normally Closed557.7.2 Define Operating or Standby Mode567.7.3 Enable or Disable an Output Device in Alarm Status567.7.4 Enable or Disable a Device during Emergency Power Operation567.7.5 Configure Output for Loss of Power (“Fail-Safe”)567.8 Setup System - Setup Modem & Pagers577.8.1 Modem Setup - Initialization String57Supported Modem Settings57Table 20 Supported modem settings57Default Modem Settings57Table 21 Default settings - modem57Configuring the Modem57Table 22 Country codes587.8.2 Modem Setup - Additional Features (Service Terminal Interface only)597.8.3 Pager Setup - Pager Number and PIN61Table 23 Pager dialing results61Table 24 Guidelines for dialing pagers627.8.4 Pager Setup - Communications Check (Service Terminal Interface only)637.9 Setup System - Setup System Info65Figure 11 Menu overview - Setup System Info menu657.9.1 Change Password66Change the Password66Reset Password to the Factory Default (“AAAA”)667.9.2 Change Date & Time/Automatic Daylight Saving Time667.9.3 Setup Site ID677.9.4 Connect Battery67Table 25 Battery alarms677.9.5 Backup and Upload Configuration File (Service Terminal Interface only)687.9.6 Setup Serv Ph Num - Enter Phone Number71Table 26 Service phone number dialing results71Table 27 Guidelines for dialing service phone number717.9.7 Setup Serv Ph Num - Communications Check (Service Terminal Interface only)727.9.8 Factory Defaults737.9.9 Perform Firmware Update (Service Terminal Interface only)737.9.10 Initiate Remote Alarm Test (Service Terminal Interface only)757.10 Setup Operation76Table 28 Default settings - operation features76Figure 12 Menu overview - Setup Operation menu767.10.1 Turn Automatic Sequencing On or Off777.10.2 Turn Standby Testing On or Off787.10.3 Specify Failed Standby Response78Table 29 Failed Standby response787.10.4 Specify Hold Delay Time797.10.5 Specify Restart Time797.10.6 Specify Staging807.11 Setup System - Setup I/O Matrix817.11.1 Set Up Mapping for a Digital Input81Default Mappings - Digital Inputs to Control Relays81Table 30 Default mapping of digital inputs to relays817.11.2 Set Up Mapping for an Analog Sensor Input82Map Sensor to Control Relay82Default Mappings - Analog Inputs to Control Relays82Table 31 Default mapping of analog inputs to relays827.12 Override Output83Table 32 Automatic / manual control - output points837.13 Clear Alarms & Logs847.13.1 Clear Active Alarms847.13.2 Clear the Alarm Log847.13.3 Clear the Event Log857.13.4 Clear the Trend Logs858.0 Specifications868.1 AC8 Specifications86Appendix A - Service Terminal Interface87A.1 Comparison of Functions: LCD and Service Terminal Interface87Table 33 Guide to AC8 functions87A.2 Connecting to the Service Terminal Interface88A.2.1 Connection Methods88Table 34 Steps to set up a direct or remote connection88A.2.2 Create a Connection88A.2.3 Set Up the COM1 Port - Direct Connection Only89COM1 Port Setup89A.2.4 Set Up the Connection’s Properties90Properties Setup90ASCII Setup90A.2.5 Connect to the Service Terminal Interface91A.3 Overview of Menus92A.3.1 View Status Overview92A.3.2 Silence Alarm and Backup Log Files92A.3.3 Setup Menu Overview92A.4 View Status Menus93Main Menu93A.4.1 View Active Alarms93A.4.2 View Alarm Log94A.4.3 View Event Log95A.4.4 View Trend Log96A.4.5 View Input Status97A.4.6 View Output Status97A.4.7 View Pager Numbers98A.4.8 View Operation99A.4.9 View Control Status99A.5 Silence Alarm & Back Up Log Files (Service Terminal Interface only)100Main Menu100A.5.1 Silence Alarm (Service Terminal Interface only)100A.5.2 Back Up Log Files (Service Terminal Interface only)101Back Up Alarm Log File101Back Up Event Log File101Back Up Trend Log Files102A.6 Setup Menu103Main Menu103Login Menu103Setup Menu104A.6.1 Setup Inputs105A.6.2 Setup Common Alarm105A.6.3 Setup Sensor106A.6.4 Setup Zones107A.6.5 Setup Output107A.6.6 Setup Modem & Pagers108Pager Setup108Modem Setup109A.6.7 Setup System Info110Change Password110Set Date & Time/Automatic Daylight Saving Time111Setup Site ID111Connect Battery111Backup and Upload Configuration File (Service Terminal Interface only)112Setup Service Phone Number113Factory Defaults113Firmware Update (Service Terminal Interface only)114Initiate Remote Alarm Test (Service Terminal Interface only)114A.6.8 Setup Operation115Auto Sequencing115Standby Testing116Failed Standby117Hold Delay118Restart Delay119Staging120A.6.9 Override Output121A.6.10 Clear Alarms & Logs122Clear Active Alarms122Clear the Alarm Log122Clear the Event Log123Clear the Trend Logs123A.6.11 Setup I/O Matrix124Appendix B - Default Settings Quick Reference Guide125Table 35 AC8 - default settings for inputs and outputs125Table 36 AC8 - other default settings126Größe: 5,16 MBSeiten: 128Language: EnglishHandbuch öffnen