Campbell Hausfeld IN629500AV User Manual

Page of 68
12
Operating Instructions and Parts Manual
www.chpower.com
Installation (Continued)
WIrIng
1.  Local electrical wiring codes differ from area to area. Source 
wiring, plug and protector must be rated for at least the 
amperage and voltage indicated on motor nameplate, and 
meet all electrical codes for this minimum.
2.  Use a slow blow fuse or a circuit breaker.
 
Overheating, short circuiting and fire damage 
  will result from inadequate wiring, etc.
NOTE: 120 volt, 15 amp units can be operated on a 120 volt 
circuit under the following conditions:
a.  No other electrical appliances or lights are connected to 
the same branch circuit.
b.  Voltage supply is normal.
c.  Circuit is equipped with a 15 amp circuit breaker or a 15 
amp slow blow fuse.
3.  If these conditions cannot be met or if nuisance tripping 
of current protection device occurs, it may be necessary to 
operate compressor from a 120 volt, 20 amp circuit.
Operation
MoISture In CoMPreSSeD AIr
Moisture in compressed air will form into droplets as it 
comes from an air compressor pump. When humidity is 
high or when a compressor is in continuous use for an 
extended period of time, this moisture will collect in the 
tank. When using a paint spray or sandblast gun, this water 
will be carried from the tank through the hose, and out of 
the gun as droplets mixed with the spray material.
IMPORTANT: This condensation will cause water spots 
in a paint job, especially when spraying other than water 
based paints. If sandblasting, it will cause the sand to cake 
and clog the gun, rendering it ineffective. A filter in the air 
line (MP3105), located as near to the gun as possible, will 
help eliminate this moisture.
This compressor can be used for general inflation as well as 
intermittent duty air tool usage. For inflation purposes, this 
compressor utilizes a new technology called Rapid Inflation 
Technology (RIT). 
IMPORTANT: Make sure the Wheel Lock/Foot Brake is engaged 
before operating the unit (See Figure 11).
LubrICAtIon
This is an oilless product and DOES NOT require lubrication to 
operate.
Figure 13  
Click-to-set 
regulator
Tank 
Pressure 
Gauge
ASME 
Safety Valve
Outlet (Tool) 
Pressure Gauge
Storage Trays