Campbell Hausfeld IN629500AV User Manual

Page of 68
18
Operating Instructions and Parts Manual
www.chpower.com
Troubleshooting Guide
SyMPtoM
CAuSe
SoLutIon
Compressor will not run
1.  No electrical power
1.  Plugged in? Switch on? Check fuse/breaker
2.  Breaker open
2.  Reset, determine cause of problem
3.  Pressure switch bad
3.  Replace
4.  Motor over worked
4.  Turn off, let cool, turn on.
5.   Tank pressure above cut-in
5.  Bleed tank pressure down to cut-in.
Fuses blow/circuit breaker 
trips repeatedly
1.  Incorrect size fuse, circuit overloaded
1.  Check for proper fuse, use time-delay fuse. 
Disconnect other electrical appliances from circuit 
or operate compressor on its own branch circuit
2.  Worn check valve
2.  Replace
 
Do not disassemble check valve with  
   air in tank; bleed tank
Tank pressure drops when 
compressor shuts off
1.  Loose connections (fittings, tubing, 
etc.)
1.  Check all connections with soap and water 
solution. Tighten; or remove and apply pipe dope 
or pipe tape to the threads, then reassemble.
2.  Open tank drain
2.  Close drain
Air output lower than 
normal/low discharge 
pressure
1.  Air leaks in piping (on machine or in 
outside system)
1.  Check all connections with soap and water 
solution. Tighten; or remove and apply pipe dope 
or pipe tape to the threads, then reassemble.
2.  Piston ring worn
2.  Replace
3.  Excessive air usage
3.  Decrease air usage; compressor not large enough 
for air requirement
4.  Open tank drain
4.  Close tank drain
Excessive moisture in 
discharge air
1.  Excessive water in tank
1.  Drain tank
2.  High humidity
2.  Move to area of less humidity; use air line filter
Compressor runs 
continuously
1.  Defective pressure switch
1.  Replace switch
2.  Excessive air usage
2.  Decrease air usage; compressor not large enough 
for air requirement
Motor runs but no air output
Belt worn
Replace belt