S A F E T Y    P R E C A U T I O N S 
 
FOLLOW ALL WARNINGS AND CAUTIONS 
ALL PUMPS: 
DO NOT
  place oil-less air pump in an area that cannot GUARANTEE clean Grade D breathable air, per OSHA 29 
CFR 1910.134 to the AABA inlet.  See below for Grade D requirements. 
DO NOT  attempt to service the air pump while it is running or while it is connected to electrical or air power. 
DO NOT  oil or lubricate the pump. 
DO NOT  kink power cord and never allow the cord to come in contact with oil, grease, hot surfaces, or chemicals. 
DO NOT  use ungrounded electrical receptacles. 
DO NOT use undersized electrical extension cords or wiring. 
DO NOT  use the pump as an air-filtering device for vapors, gases, or particulates. 
DO NOT  start pump without respirator(s) and hose(s) connected to pump. 
DO NOT  use Vortex type cooled respirators with Allegro pumps. 
DO check all airline hoses for weakness and wear before use. 
DO Ensure that all hose and plumbing connections are secure. 
DO Ensure that the power source conforms to the requirements of your equipment. 
DO remove aluminum canister on exhaust filter assembly and check that exhaust filter is firmly seated in 
place before startup. 
 
AIR DRIVEN PUMP: (P/N 9850)  
 
DO NOT  attempt to service the air pump or air motor while it is in operation, and air source connected. 
DO NOT  run air motor with less than 75 cfm at 80 psi. 
DO NOT  run air motor with dirty particulate filter. 
DO run air motor with inline lubrication properly filled and adjusted.  
DO make sure that the air pressure and volume conforms to the requirements of your equipment. 
 
EXPLOSION PROOF PUMP: (P/N 9833) 
 
DO NOT  remove plug or cord from motor.  Hazardous location plug and receptacle must be used at all times. 
DO NOT  place pump’s inlet filter (or extension) in a hazardous location. 
 
 
 
DO ensure proper electrical power to motor. 
 
 
 
DO ensure proper cooling for electrical motor, to avoid heat sources in a hazardous location. 
 
NOTE:  For further information on how to operate Allegro AABA pumps with various NIOSH approved 
respirators, please contact our Technical Support Department. 
 
 
WARNING! 
 
DO NOT run pump without attaching the breathing hose and respirator.  Failure to do so may result in a "back 
pressure" causing damage and/or stalling the pump.  
 
 
 
C.G.A. Grade-D Air Requirements 
 
 
Oxygen 
   
 
 
 
 
 
19.5 - 23.0 %  
 
Hydrocarbons (condensed) in mg/m3 of gas   
5 mg/m
3
 Max. 
 
Carbon 
Monoxide 
 
      10 
ppm 
Max. 
 
 
Carbon 
Dioxide 
 
      1,000 
ppm 
Max. 
 
 
No toxic contaminants at levels which would make the air unsafe to breathe.