Centurion M23/8500 User Manual

Page of 8
                024-001-750  MOD 8     11/05/07                            Page 2 of 8                                POWER UNITS
Centurion Safety Products Ltd. Howlett Way, Thetford, Norfolk, IP24 1HZ, UK
Tel. 0044 (0)1842 754266   Fax. 0044 (0)1842 765590
Compatibility between Headpieces and Power Units:
Headpieces:
Power Units:
Description
Code
1000/2000
8500      
Rigid Polycarbonate Visor with Saronex Hood
M23RVSN
 


Flip up Polycarbonate Visor
M23FUVN
 

                

Helmet with Flip-up Polycarbonate Visor
                M23HFUV
 


High Temperature Helmet with Clear Triacetate Flip up Visor                M23HFUVHTT
 

High Temperature Helmet with Gold Polycarbonate Visor
                M23HFUVHTGP       

Automatic Welding Visor
M23AWSN
 


Fixed Shade Welding Visor
M23FSWN
 


Full Facemask with Twin Hose
M23FF
 x

Full Hood without airflow indicator
M23FH/8
 x

Half Suit without airflow indicator
M23HS/8
 x
               

Lightweight P3 Tyvek F
                                               M23LHF

               

3.
APPLICATIONS AND LIMITATIONS
When  used  with  filters  M23P3/5,  M23P2/5  or  M23P3SL/6  the  Magnum  respirator  will  offer  protection  against  dusts,  particles,  fumes  and  aerosols
(solid and liquid based) to the levels detailed.
No protection is given against gases or vapours.
The  Magnum  system  should  not  be  used  where  airborne  concentration  of  contaminant  exceeds  the  Assigned  Protection  Factor  (APF)    x    the
Occupational exposure limit (OEL)
The system is recommended for use in the temperature range +5° to +35°C and in conditions where relative humidity does not exceed 90%.
Protection Factors
The efficiency of all types of respirators is classified by the protection factor rating system. There are two main classifications for protection factors,
these are:
Laboratory Protection Factor  (also known as Nominal Protection Factor)
This is the minimum level of protection the equipment has  to  demonstrate  for  each  of  a  panel  of  test  subjects  under  laboratory  conditions  to  gain
approval to the appropriate class of the performance standard.
Assigned Protection Factor (APF)
BS4275 or EN 529 acknowledges that laboratory performance is not always achievable in real use.
These figures are taken from BS4275: 1997 and are the minimum level of protection which it is calculated 95% of wearers who are trained in the use
of  the  equipment  should  achieve  in  practice,  with  well-maintained  equipment.  These  figures  are  valid  for  use  in  the  UK  and  may  differ  in  other
countries.
For further information regarding protection factors please contact our technical advice service.
4.
PREPARATION FOR USE
Battery
The  power  unit  is  fitted  with  a  rechargeable  battery  pack,  which  requires  charging  before  use.  Ensure  you  are  using  the  correct  charger  for  your
battery pack (See Section 2).
Standard Charger (M23P2/4BC or M23HD4BC) –
When charging the battery connected to a Turbo unit the turbo unit must be turned off.
Plug the charger into an appropriate mains supply.  Connect the battery charger plug to the charger socket on the battery pack. The LED indicator
will light if the charging circuit is satisfactory.
Batteries are supplied in a discharged condition, and must initially be charged for 20 hours before use. Subsequent charges only require 16 hours.
IOvercharging the batteries may permanently damage them.
Intelligent Charger (M23UIC) – This charger will charge all Magnum battery packs and will operate on both UK and European Voltages.
To change the mains plug from European to UK and vice versa unplug charger from mains and push up switch marked “Open” in the direction of
the arrow the plug should then pop out. Insert the replacement plug into the charger pushing firmly until it “clicks home” Batteries may be charged
on or off the turbo unit.
Batteries must be charged indoors at an ambient of between 10ºC and 30ºC. Do not cover charger.
Important : In excessive cold or warm environments the recharging device may suppress the charging current to standby level so the battery will
be not be charged.  Never charge in a potentially explosive atmosphere.
To use : Plug the charger into the main power supply (100 – 240V AC – 50-60 HZ). When no battery is connected, the LED (Light emitting Diode)
indicators light on the front of the charger should not be lit.
When charging the battery connected to a Turbo unit the turbo unit must be turned off.
Plug the charging connector into the socket in the rear of the battery pack.
The RED LED indicator will flash for a few seconds indicating that the charger is checking the status  of  the  battery  pack.  The  RED  LED  should
then light continuously indicating that the battery is being charged.
When the  battery  is  fully  charged  the  RED  LED  will  go  out  and  the  GREEN  LED  will  indicate.  At  this  point  the  battery  will  be  in  “trickle  charge”
mode, this will maintain the battery’s charge. The battery can be left permanently connected, if desired, until required for use.
Note : A new battery, a battery stored for a very long period or a battery that has been run completely flat so that is deeply discharged* may not
function correctly.
If when starting to charge such a battery the RED LED continues flashing for more than 10 seconds the charger has detected either a very deeply
discharged battery or a faulty battery.