Adtran 1204002L2 User Manual
Chapter 3. Operation
61200275L1-1
TSU IQ+ User Manual
3-5
VT-100 Terminal Connection and Operation
To control the TSU IQ+ using a VT-100 terminal, follow this
procedure:
procedure:
1.
Using the front panel interface, set the TSU IQ+ baud rate to
match the terminal. Select
match the terminal. Select
1 C
ONFIG
; then select
C
ONTROL
P
ORT
.
2.
Using the ADTRAN-provided VT-100 terminal adapter,
connect the
connect the
COM
port of a VT-100 compatible terminal or
equivalent to the eight-pin modular jack labeled
CONTROL
on
the rear of the TSU IQ+. This connection is used for both local
and remote configuration.
and remote configuration.
3.
Open the connection and press
Enter
repeatedly until the
L
OGIN
Menu appears (Figure 3-3 on page 3-6).
4.
Select
L
OCAL
L
OGIN
to configure the TSU IQ+ unit connected to
the terminal.
5.
Select
R
EMOTE
L
OGIN
to configure a remotely located TSU IQ+
unit.
6.
For remote applications, at the remote DLCI prompt, enter the
outgoing DLCI (see the following note) by pressing
outgoing DLCI (see the following note) by pressing
1
, then
Enter
, entering the DLCI number, and pressing
Enter
again.
7.
Select
B
EGIN
R
EMOTE
S
ESSION
by pressing
2
and
Enter
.
8.
Enter the password. The factory default password is
adtran
.
The
M
AIN
menu will appear (Figure 3-4 on page 3-6).
9.
Make selections by entering the number corresponding to the
chosen parameter. Press
chosen parameter. Press
ESC
to return to the previous screen.
When entering the DLCI for a remote application, enter the DLCI associ-
ated with the local unit that you are logged into (not the far end DLCI).
ated with the local unit that you are logged into (not the far end DLCI).
If the wrong DLCI is entered or a network problem exists, the screen freez-
es at the
es at the
P
RESS ANY KEY TO CONTINUE
prompt. Press
CNTL
+
L
twice
to return the unit to the
L
OGIN
screen.