19  BUILT-IN I/O FUNCTION
19.3  Pulse Width Measurement Function
Details of special relays/special registers
Details of special relays/special registers used in pulse width measurement are explained below.
Pulse width measurement status flag
This flag is a device for monitoring the measurement in progress/measurement stopped status of pulse width measurement.
Corresponding devices
The device numbers corresponding to each channel are as follows.
Update timing
This device turns ON when the HIOEN instruction is executed. It turns OFF at the END instruction when the measurement 
mode is the 1 time measurement mode.
Clear timing
The timing when the device is cleared is as follows.
  • Power  OFF
ON
 • Reset
  • STOP/PAUSE
RUN
 • RUN
STOP/PAUSE
 • When measurement is stopped by the HIOEN instruction
Rising edge flag
This flag turns ON at the end of the 1st period measurement. During measurement in the always measurement mode, it stays 
ON.
Corresponding devices
The device numbers corresponding to each channel are as follows.
Update timing
Devices are updated by the END instruction.
Clear timing
The timing when the device is cleared is as follows.
  • Power  OFF
ON
 • Reset
  • STOP/PAUSE
RUN
 • When measurement is started by the HIOEN instruction
When the HCMOV instruction is used, the latest value can be read.
SD5087, SD5086
CH4 pulse width maximum value
The maximum value of the pulse width is stored.
00000000H
R/W
SD5089, SD5088
CH4 pulse width minimum value
The minimum value of the pulse width is stored.
FFFFFFFFH
R/W
SD5091, SD5090
CH4 period latest value
The latest value of the period is stored.
00000000H
R/W
SD5093, SD5092
CH4 period maximum value
The maximum value of the period is stored.
00000000H
R/W
SD5095, SD5094
CH4 period minimum value
The minimum value of the period is stored.
FFFFFFFFH
R/W
CH1
CH2
CH3
CH4
SM5020
SM5021
SM5022
SM5023
CH1
CH2
CH3
CH4
SM5036
SM5037
SM5038
SM5039
Special relays/
special 
registers
Function
Description
Default
R/W