Seiko 7K52 User Manual

Page of 32
English
31
SPECIFICATIONS
 1
Frequency of crystal oscillator ...................
32,768 Hz (Hz = Hertz ... Cycles per second)
 2
Loss/gain (monthly rate) .............................
Less than 15 seconds at normal temperature range (5
°
 C
~ 35
°
 C) (41
°
 F ~ 95
°
 F)
 3
Operational temperature range ..................
–10
°
 C ~ +60
°
 C (14
°
 F ~ 140
°
 F)
0
°
  C ~ +40
°
  C (32
°
  F ~ 104
°
  F) for water depth
measurement function
 4
Driving system ...........................................
Step motor, 4 pieces
 5
Display system
TIME/CALENDAR display .......................
Hour, minute and small second hands and date
DEPTH MEASUREMENT display ............
Current depth by DEPTH hand and 1/10 m hand
Maximum depth by MAX. DEPTH hand (in 0.5 m
increments)
Diving time by DIVING TIME hand (in 1/5 minute
increments)
Time submerged by the small hour and minute hands at
the 6 o’clock position
LOG DATA display ..................................
Stores details of two dives.
Maximum depth by MAX. DEPTH hand (in 0.5 m
increments)
Average depth by DEPTH hand and 1/10 m hand
Diving time by DIVING TIME hand (in 1/5 minute
increments)
Time submerged by the small hour and minute hands at
the 6 o’clock position
ALARM display .......................................
Small hour and minute hands at the 6 o’clock position
• While disengaged
: Current time
• While engaged
: Designated alarm time