Emerson Process Management 3051N User Manual

Page of 100
Reference Manual 
00809-0100-4808, Rev CA
June 2008
Rosemount 3051N
www.rosemountnuclear.com
Section 5
Specifications and 
Reference Data
NUCLEAR 
SPECIFICATIONS
Qualified for nuclear use per IEEE Std 344-1987 and IEEE Std 323-1983 (mild 
environment) as documented in Rosemount Report D2001019
Seismic
Table 5-1. Seismic Specifications Summary
Model
Range 
Code
During Seismic 
Accuracy
(1)
(1) User-adjustable damping set at 
≥ 0.4 s unless otherwise noted.
Post Seismic Accuracy
Specified Seismic Maximum 
Working Pressure
Structural 
Integrity
3051ND
0
not specified
not specified
750 psi (5,2 MPa)
Maintained 
throughout 
specified seismic 
disturbance
1
(2)
(2) Mounting bracket (Option Code B2, BS, or PM) required for specified “During Seismic Accuracy” performance.
0.75% of URL 
(adjustable damping  
≥ 1.6 s)
0.25% of span
2000 psi (13,8 MPa)
0.75% of URL 
(adjustable damping 
≥ 
0.8 s)
3000 psi (20,7 MPa)
(glass-filled TFE o-ring)
2000 psi (13,8 MPa) 
(EP o-ring)
3
0.75% of URL
4
0.25% of URL
5
3051NG
0.75% of URL 
(adjustable damping  
≥ 0.8 s)
Upper Range Limit
3
0.75% of URL
4
0.25% of URL
5
3051NA
0
not specified
not specified
1
2
0.25% of URL
0.25% of span
3
4
3000 psia 
(glass-filled TFE o-ring)
2000 psi (13,8 MPa)
(EP o-ring)
Dif
fer
ential
Gauge
Absolute