Agilent Technologies E6380-90073 User Manual

Page of 352
218
Chapter 1
 
GPIB Command Dictionary
MEASure subsystem
:CANalyzer:ADC:EVMadc:LEVel <meas cmnd>
:CANalyzer:ADC:EVMadc:LEVel?
These commands set/query the ADC for the EVM measurement. The 
ADC is a measure of how close the actual input signal is to the 
maximum input level.
This measurement utilizes the Number Measurement Syntax, but does 
not use the :METer command.
Syntax
MEAS:CAN:ADC:EVM:LEV <meas cmd> 
MEAS:CAN:ADC:EVM:LEV?
Example
MEAS:CAN:ADC:EVM:LEV? !displays the measurement 
Screen/field equivalent
MEAS:CAN:ADC:EVM:LEV? reads the 
ADC FS
 measurement field on 
the CDMA ANALYZER screen when an EVM measurement is selected.
:CANalyzer:ADC:RHOadc:LEVel <meas cmnd>
:CANalyzer:ADC:RHOadc:LEVel?
These commands set/query the ADC for the rho measurement. The 
ADC is a measure of how close the actual input signal is to the 
maximum input level.
This measurement utilizes the Number Measurement Syntax, but does 
not use the :METer command.
Syntax
MEAS:CAN:ADC:RHO:LEV <meas cmd> 
MEAS:CAN:ADC:RHO:LEV?
Example
MEAS:CAN:ADC:RHO:LEV? !displays the measurement 
Screen/field equivalent
MEAS:CAN:ADC:RHO:LEV? reads the 
ADC FS
 measurement field on 
the CDMA ANALYZER screen when a rho measurement is selected. 
This measurement is also displayed on the CDMA GENERATOR 
screen.