ADC AD-26 User Manual
38
G. PROGRAM LOCATION 04 (PL04)
HI Temp cool down temperature/time
Location to be viewed/changed.
Press “Perm Press” key.
Display will read “HICd,” HI Temp
cool down status for 3-seconds and then
the actual temp and time programmed.
If no change press “Perm Press” key twice,
otherwise press “HI” or “LO” keys and
then “Perm Press” key.
cool down status for 3-seconds and then
the actual temp and time programmed.
If no change press “Perm Press” key twice,
otherwise press “HI” or “LO” keys and
then “Perm Press” key.
Summary: Cool down temperature is programmable from a minimum of 70° F to a maximum of 190° F in ten
degree increments or from a minimum of 21° C to a maximum of 88° C in five-degree increments.
For the AD-26 and AD-295 any three (3) of the selections (HI/LO/PP) are programmable from a
minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to
a maximum of 77° C in five-degree increments.
minimum of 100° F to a maximum of 170° F in ten-degree increments or from a minimum of 38° C to
a maximum of 77° C in five-degree increments.
For the AD-540 and WDA-540 any three (3) of the selections (HI/LO/PP) are programmable from
a minimum of 100° F to a maximum of 160° F in ten-degree increments or from a minimum of 38° C
to a maximum of 71° C in five-degree increments.
to a maximum of 71° C in five-degree increments.
Cool down is programmable from 0 to 9 minutes.
PL04
HICd
Perm Press
·
100
·
2
HI Temp
Perm Press
LO Temp
Refer to Section V for instructions
on entering program locations.
(Wait 3-Seconds)
Continued from F.
100
·
2
LO Temp
HI Temp
Perm Press
PL05
Proceed to next location
to be changed
To exit program mode,
open program switch
Temperature Decrease
Temperature Increase
Time Decrease
Time Increase