D.  DUAL COIN ONLY
For dryer models AD-26/AD-295  and  AD-540/WDA-540  ONLY
PL01 - °FAr
- Temperatures in Fahrenheit
tInE
- Timed mode
Grd
- Anti-wrinkle guard on
bUZ
- Anti-wrinkle guard buzzer (tone) on
Coin
- Coin(s) required to start
FLS
- Display will flash in intervals between “FILL” and “Amount To Start”
bCrS
- Bad coin reset
AtIn
- Accumulative time
nSEn
- Rotational sensor not selected
PL02 - PdrY
- Percent Dry  -  98%
PL03  - HI
O
F
- 150°
PL04  - HICd
- Temperature - 80°, Time - 2 minutes
PL05 - LO°F
- 120°
PL06  - LOCd
- Temperature - 80°, Time - 2 minutes
PL07 - PP°F
- 130°
PL08  -  PPCd
- Temperature - 80°, Time - 3 minutes
PL09  - LCdE
-  Left coin denomination - 25¢
PL10  - rCdE
- Right coin denomination - 10¢
PL11  - tFAS
- Time for amount to start - 10 minutes
PL12  - AtSt
- Amount To Start - 25¢
PL13  -  AFAt
- Amount for additional time - 25¢
PL14  - Adrt
- Automatic dry maximum time - 30 minutes
PL15  - GdLY
- Anti-wrinkle guard off delay time - 2 minutes
Gont
- Anti-wrinkle guard on time - 20-seconds
PL16  - AGt
- Active anti-wrinkle guard time - 10 minutes
PL17  - A and b
- “A” is adjustable from 1 to 99 (example: A = 5)
Factors
- “b” is adjustable from 1 to 99 (example: B = 70)