Exhaust System
IMPORTANT:  Keep exhaust duct as short as 
possible.
NOTE:  Be certain old ducts are cleaned before 
installing your new dryer.
For best drying results, recommended maximum length 
of exhaust system is shown below.
To prevent backdraft when dryer is not in operation, 
outer end of exhaust pipe must have a weather hood 
with hinged dampers (obtain locally).
NOTE:  Weather hood should be installed at least 
12 inches (30.5 cm) above the ground. Larger 
clearances may be necessary for installations where 
heavy snowfall can occur.
Exhaust Direction
The dryer can be exhausted to the outdoors through the 
back, left, right or bottom of the dryer. EXCEPTION: 
Gas dryers cannot be vented out the left side 
because of the burner housing.
Dryer is shipped from factory ready for rear exhaust; 
no kits required
.
Exhausting the dryer through sides or bottom can be 
accomplished by installing a DK1 Sales Accessory  
(Directional Exhaust Kit 528P3) available as optional 
equipment at extra cost.
D328IE0A
528P3 Directional Exhaust Kit
Number of 
90° Elbows
Weather Hood Type
Recommended
Use only for short run installations
Maximum length of 4" (10.2 cm) diameter rigid metal duct.
0
44 feet (13.4 m)
34 feet (10.4 m)
1
34 feet (10.4 m)
26 feet (7.9 m)
2
26 feet (7.9 m)
20 feet (6.1 m)
3
20 feet (6.1 m)
14 feet (4.3 m)
Maximum length of 4" (10.2 cm) diameter flexible metal duct.
0
24 feet (7.3 m)
20 feet (6.1 m)
1
20 feet (6.1 m)
16 feet (4.9 m)
2
16 feet (4.9 m)
12 feet (3.7 m)
3
12 feet (3.7 m)
8 feet (2.4 m)
NOTE: Deduct 6 feet (1.8 m) for each additional elbow.