Installation
Pre-Installation Inspection
Upon delivery, visually inspect the crate, carton and 
parts for any visible shipping damage. If the crate, 
carton, or cover is damaged or signs of possible 
damage are evident, have the carrier note the condition 
on the shipping papers before the shipping receipt is 
signed, or advise the carrier of the condition as soon as 
it is discovered.
Remove the crate and protective cover as soon as 
possible and check the items listed on the packing list. 
Advise the carrier of any damaged or missing articles 
as soon as possible. A written claim should be filed 
with the carrier immediately if articles are damaged or 
missing.
IMPORTANT: Remove the shipping tape from the 
two back draft dampers located in the exhaust 
outlet.
IMPORTANT: Warranty is void unless tumbler is 
installed according to instructions in this manual. 
Installation should comply with minimum 
specifications and requirements detailed in this 
manual and applicable local gas fitting regulations, 
municipal building codes, water supply regulations, 
electrical wiring regulations, and any other 
relevant statutory regulations. Due to varied 
requirements, applicable local codes should be 
thoroughly understood and all pre-installation 
work arranged for accordingly.
IMPORTANT: Keep tumbler area clear and free 
from combustible materials, gasoline and other 
flammable vapors and liquids.
NOTE: 3 Phase Only – Each tumbler must be 
connected to its own individual branch circuit 
breaker, not fuses, to avoid the possibility of “single 
phasing” and causing premature failure of the 
motor(s).
Materials Required (Obtain Locally)
All Models
One Single Pole fused disconnect 
switch or circuit breaker on 1 Phase 
models.
Circuit breaker on 3 Phase models.
Gas Models
One gas shut-off valve for gas service 
line to each tumbler.
Steam Models
One steam shut-off valve for steam 
service line to be connected upstream of 
solenoid steam valve.
Two steam shut-off valves for each 
condensate return line.
Flexible steam hoses with a 125 psig 
(pounds per square inch gauge) 
(8.79 kg/sq. cm) working pressure for 
connecting steam coils. Refer to Figure 
23
 
for sizing and connection 
configurations.
Two steam traps for steam coil outlets 
to condensate return line.
Optional – Two vacuum breakers for 
condensate return lines.