Installation
25
M414905
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Required for CE Models Only
Once machine is installed, please be sure to complete 
the following items:
Review and verify machine operation with 
customer.
Leave all literature and a signed Declaration of 
Conformity with customer.
Review machine warranty information with 
customer.
Apply warning sticker on front panel of machine, 
in language appropriate to country of sale 
(included in literature packet).
Installing CE Gas Drying Tumblers
General Information
This information is to be used when installing gas 
tumblers in countries and/or on gases different than the 
machine’s factory configuration. Tumblers are 
supplied from the factory for operation on Natural Gas 
1000 Btu/cu ft. (8914 kcal/m
3
), or L.P. Gas 2500 Btu/
cu ft. (22,250 kcal/m
3
),in the countries of GB/IE/PT/
ES/IT/GR/LU/CH. To install machines in any other 
country, or on any other gas, requires some level of 
modification.
Machines are built in two different configurations:
Natural Gas – regulated/governor 
Liquefied Petroleum (L.P.) Gas – not regulated/
no governor
Machines configured for Natural Gas (regulator/
governor) may be converted to L.P. Gas (not regulated/
no governor) with block-open kit, Part No. M400763. 
Serial plates supplied from the factory are configured 
for GB/IE/PT/ES/IT/GR/LU/CH. These instructions 
pertain to the situations when the country of use or gas 
supply is different than that on the serial plate.
Table 1 describes the different gases that are available 
in different CE countries, and how the machines need 
to be configured to operate with those gases. In the 
CE, there are Natural Gas configurations that do not 
allow for machine regulation and L.P. Gas 
configurations that must be regulated. For L.P. Gas, 
third family B/P at 50 mbar, order Regulated Natural 
Gas machines and convert according to Table 1.
WARNING
To reduce the risk of electric shock, fire, 
explosion, serious injury or death:
• Disconnect electric power to the 
tumbler before servicing.
• Close gas shut-off valve to gas tumbler 
before servicing.
• Close steam valve to steam tumbler 
before servicing.
• Never start the tumbler with any guards/
panels removed.
• Whenever ground wires are removed 
during servicing, these ground wires 
must be reconnected to ensure that the 
tumbler is properly grounded.
W002