Installation Instructions
23
M412060
1. Install a fused disconnect switch, or a circuit 
breaker, as close to the tumbler as possible. If 
more than one stacked tumbler is being installed, 
provide a disconnect switch or circuit breaker for 
each. This will make it possible to individually 
disconnect stacked tumblers for maintenance 
purposes.
2. Connect the conduit-encased leads to the 
disconnect switch, or circuit breaker. Remove the 
screw holding the upper junction box cover to the 
upper junction box. Refer to Figure 10. Insert the 
other end of conduit through the hole in the top 
of the junction box. Connect the wire leads to the 
appropriate terminals of the terminal block 
(L1 and L2 or L1 and N). If the electrical service 
is 120 Volt, connect the neutral wire to 
NEUTRAL. The ground wire must be connected 
to the green ground screw located in the junction 
box. Refer to Figure 10.
3. Reinstall cover on the junction box.
Grounding Instructions
This drying tumbler must be grounded. In the event of 
malfunction or breakdown, grounding will reduce the 
risk of electronic shock by providing a path of least 
resistance for electric current. This dryer must be 
connected to a grounded metal, permanent wiring 
system or to the ground screw (located in the junction 
box).
To reduce the risk of fire and electric 
shock, check with a qualified 
serviceperson for proper grounding 
procedures. Improper connection of the 
equipment grounding conductor may 
result in a risk of electric shock.
W068R1
WARNING
Figure 10
TMB2161N
IEI 
Board
Terminal 
Block
Terminal
Jumper 
Block
Ground
Screw