Diagnostic Microprocessor Control
General Operation
The Diagnostic Microprocessor Control (DMP) is 
designed to manage the drying and cooling cycles of 
the tumbler. The controller is also programmed from 
the factory with five different default programs as 
described below. The operator has the flexibility to 
select the time for the drying and the cool down cycles 
and the drying temperature. The operator may also 
select either reversing or nonreversing basket action 
only if the tumbler is equipped for reversing. The 
operator may also reprogram the default programs. 
See Programming. 
Default Programs
Features
Drying time: 0-60 minutes
Cooling time: 2-60 minutes
LED display of cycle time, set temperature, and 
actual    temperature
Thermistor controlled temperature
Safety tumble cycle 
Buzzer for end of cycle, audible alarm
Reversing/Nonreversing selection
Five user programmable programs
RPM display – when equipped with rotational 
   sensor only
Monitors the lint door switch operation
Monitors the thermistor for operation
The minimum drying time is 0 minutes, and the 
minimum cooling time is 2 minutes. The maximum 
drying or cooling time is 60 minutes. The drying 
temperature may be set from 100ºF (38ºC) to 185º/
195ºF (85º/91ºC). The drying time, cooling time, or 
temperature may be modified during an operating 
cycle.
If it is necessary to reset the drying and cooling times 
for the current cycle, press STOP once to stop the 
tumbler. Press STOP again to cancel the cycle. 
If it is necessary to change programs during a current 
cycle, press STOP once to stop the tumbler and press 
STOP again to cancel the current cycle. 
Programs 
Dry Time (Min.)
Cool Time (Min.)
Temp. Set Point
Reversing
1 – Towels
40
185º/195ºF
 (85º/91ºC)
No
2 – Sheets
30
5
165ºF (74ºC)
Yes
3 – Misc-1
30
5
150ºF (66ºC) 
No
4 – Misc-2
25
5
135ºF (57ºC)
Yes
5 – Extra Dry
5
2
150ºF (66ºC)
No
NOTE: If an altered program is determined to be corrupted, the default program settings will be used.
Table 1