Installation
IMPORTANT: Warranty is void unless tumbler is 
installed according to instructions in this manual. 
Installation should comply with minimum 
specifications and requirements detailed in this 
manual and applicable local gas fitting regulations, 
municipal building codes, water supply regulations, 
electrical wiring regulations, and any other 
relevant statutory regulations. Due to varied 
requirements, applicable local codes should be 
thoroughly understood and all pre-installation 
work arranged for accordingly.
Pre-Installation Inspection
Upon delivery, visually inspect the packaging and 
portions of the product visible through the packaging 
for shipping damage. If the package or product is 
damaged or if signs of possible damage are evident, 
have the carrier note the condition on the shipping 
papers before the shipping receipt is signed, or advise 
the carrier of the condition as soon as it is discovered.
Remove the crate and protective cover as soon as 
possible and check the items listed on the packing list. 
Advise the carrier of any damaged or missing articles 
as soon as possible. A written claim should be filed 
with the carrier immediately if articles are damaged 
or missing.
IMPORTANT: Keep tumbler area clear and free 
from combustible materials, gasoline and other 
flammable vapors and liquids.
Materials Required (Obtain locally)
All Models
One fused disconnect switch or 
circuit breaker.
Gas Models
One gas shut-off valve for gas 
service line to each tumbler.
Steam Models
One steam shut-off valve for steam 
service line to be connected 
upstream of solenoid steam valve.
Two steam shut-off valves for each 
condensate return line.
Flexible steam hoses with a 125 psig 
(pounds per square inch gauge) 
(8.79 kg/sq. cm) working pressure 
for connecting steam coils. Refer to 
Figure 16 and Figure 17 for sizing 
and connection configurations.
Three steam traps for steam coil 
outlet to condensate return line.
Three vacuum breakers for 
condensate return lines.