Alliance Laundry Systems T433I User Manual

Page of 116
Gas Requirements
M414038
40
© Copyright, Alliance Laundry Systems LLC – DO NOT COPY or TRANSMIT
Instant Electronic Ignition System
To light and shut down Instant Electronic Ignition 
system:
1. Remove access panel.
2. Turn gas shut-off valve to open position 
(handle should be parallel with the gas line). 
Refer to Figure 15.
3. Replace access panel.
4. Start tumbler in drying cycle. Spark igniter will 
begin high intensity sparking as the gas valve 
simultaneously opens. The gas burner(s) are 
ignited by the sparking igniter. Igniter will shut 
off, and burner(s) will remain on as long as the 
temperature control calls for heat.
5. Opening the tumbler door will cause flame to 
extinguish. Closing door and starting tumbler 
will restart ignition cycle.
IMPORTANT: The Instant Electronic Ignition 
system will attempt to light the gas by sparking for 
approximately 15 seconds. If gas ignition does not 
take place within 15 seconds the Instant Electronic 
Ignition control will go into safety lockout and the 
valve will no longer open until the Instant 
Electronic Ignition control is reset. To reset Instant 
Electronic Ignition control, remove power from 
control by opening and closing the loading door. If 
condition persists, check that the gas shut-off valve 
is in open position and that the gas service is 
properly connected. If condition still persists, 
remove tumbler from service.
6. To remove tumbler from service, disconnect 
electrical service, and turn gas shut-off valve to 
closed position (handle should be at right angle to 
the gas line).
Figure 15 
T087K
1
Closed Position
5
Burner Support Bracket
2
Open Position
6
Spud Holder
3
Gas Shut-Off Valve
7
Union Nut
4
Manometer
T087K
1
2
3
4
6
5
7