Electrical Requirements
NOTE: To ensure protection against shock, this 
tumbler MUST be electrically grounded in 
accordance with the local codes or, in the absence of 
local codes, with the latest edition of the National 
Electrical Code ANSI/NFPA No. 70. In Canada the 
electrical connections are to be made in accordance 
with CSA C22.1 latest edition Canadian Electrical 
Code, Part I and/or local codes. Electrical work 
should be done by a qualified electrician.
Grounding Instructions
This tumbler must be grounded. In the event of 
malfunction or breakdown, grounding will reduce the 
risk of electric shock by providing a path of least 
resistance for electric current. This tumbler must be 
connected to a grounded metal, permanent wiring 
system; or an equipment grounding conductor must be 
run with the circuit conductors and connected to the 
appropriate ground location.
Metal conduit and/or BX cable is not considered 
ground. Connecting the Neutral from the electrical 
service box to the tumbler ground screw does not 
constitute a ground. A dedicated ground conduit (wire) 
must be connected between the electrical service box 
ground bar and the tumbler ground screw.
To reduce the risk of electric shock, fire, 
explosion, serious injury or death:
• Disconnect electric power to the tumbler 
before servicing.
• Close gas shut-off valve to gas tumbler 
before servicing.
• Close steam valve to steam tumbler 
before servicing.
• Never start the tumbler with any guards/
panels removed.
• Whenever ground wires are removed 
during servicing, these ground wires 
must be reconnected to ensure that the 
tumbler is properly grounded.
W002
To reduce the risk of fire and electric 
shock, check with a qualified serviceman 
for proper grounding procedures. 
Improper connection of the equipment 
grounding conductor may result in a risk 
of electric shock.
W068
To reduce the risk of fire and electric 
shock, if electrical supply is coming from a 
three phase service, DO NOT connect a 
“High Leg” or “Stinger Leg” to a single 
phase machine. On a three phase machine, 
if there is a “High Leg” or “Stinger Leg” it 
should be connected to L3.
W069
WARNING
All electrical connections should be made 
by a qualified electrician.
To reduce the risk of electrical shock, de-
energize the electrical circuit being 
connected to the tumbler before making 
any electrical connections. Never attempt 
to connect a live circuit.
W070
WARNING
Label all wires prior to disconnection when 
servicing controls. Wiring errors can 
cause improper and dangerous operation. 
Verify proper operation after servicing.
W071
CAUTION