Adjustments
Gas Burner Air Shutter
NOTE: Air inlet shutters on the burner must be 
adjusted so sufficient air is metered into the system 
for proper combustion and maximum efficiency. 
Before adjusting the inlet shutters, be sure that all 
lint is removed from lint compartments and lint 
screen.
Air shutter adjustment will vary from location to 
location and will depend on the vent system, number 
of units installed, make-up air and line gas pressure. 
Opening the shutter increases the amount of primary 
air supplied to the burner, while closing the shutter 
decreases the primary air supply. Adjust air shutter as 
follows:
1. Remove the upper access panel.
2. Start the tumbler and check the flame pattern. 
Correct air and gas mixture is indicated if the 
flame pattern is primarily blue, with small yellow 
tips, and bends to the left of the heater section 
(refer to Figure 20). Too little air is indicated if 
the flame is yellow, lazy and smoky. A flame 
pattern that flares to the right and left (refer to 
Figure 20) indicates no air is flowing through the 
tumbler.
3. To adjust the air shutter, loosen air inlet shutter 
adjusting screw (refer to Figure 20).
4. Open or close air shutter as necessary to obtain 
proper flame intensity.
5. After air shutter is adjusted for proper flame, 
tighten air shutter adjusting screw securely. 
6. If the flame pattern is straight up (refer to 
Figure 20), insufficient primary air is flowing 
through the tumbler and airflow switch is 
improperly set. 
Figure 20 
T464I
1
Air Shutter Adjusting Screw
PROPER AIRFLOW
INSUFFICIENT AIRFLOW
NO AIRFLOW
1
1
1