Operating Instructions
70400101 (EN)
18
Ignition Control Operation for CE 
Models 
Power Up
After 24VAC is applied to the ignition control pins 
24V and GND, the Diagnostic LED on the ignition 
control will turn orange/yellow. If a fault is detected 
the ignition control will enter Lockout Mode. If no 
faults are detected, the Diagnostic LED will turn 
Green and the ignition control will enter Standby 
Mode.
Standby Mode
While in Standby Mode, the ignition control will 
continually monitor the system for faults. Once 
24VAC
 
is applied to terminals TH and GND on the 
control, the ignition control will enter Start Up Mode.
Start Up Mode
During Start Up Mode, the ignition control will 
monitor the system for faults and begin the ignition 
sequence. If no faults are present, the ignition control 
will begin the ignition sequence by entering an 18 
second waiting period. During this time the Green 
LED on the ignition control will switch between Red 
and Green, before maintaining a Green color.
After the waiting period, the ignition control will turn 
on the igniter and gas valve. The igniter will remain on 
until a flame is sensed, or up to 10 seconds. 
Once a flame has been sensed the ignition control will 
stop sparking, the gas valve will remain on and 
ignition control will enter Run Mode.
If a flame is not sensed, the ignition control will then 
begin two additional retrials for ignition. The ignition 
control will re-enter the 18 seconds waiting period 
before the ignition control makes another attempt at 
ignition. If the three attempts at ignition fail, the 
ignition control will enter Lockout Mode.
Run Mode
While in Run Mode the ignition control leaves the gas 
valve on, monitors the flame signal, and leaves the 
igniter off. 
If a flame signal is lost during Run Mode, one 
additional retrial for ignition will take place within one 
second. The ignition control will restore the spark for 
approximately 10 seconds. If the ignition re-attempt 
fails, the ignition control will enter Lockout Mode.
The ignition control will remain in Run Mode until 
24VAC is removed from terminals TH and GND on 
the control. 
Termination of Flame
The flame will go out when power is removed from 
ignition control. The ignition control will turn off the 
gas valve and enter Standby Mode.
Lockout Mode
When Lockout Mode is entered, the ignition control 
will remove power to the gas valve, the igniter will 
turn off, the Lockout/Reset Light will turn on, and the 
Diagnostic LED will display the appropriate Error 
Code.
Lockout Manual Reset
Lockout Mode is cleared by pressing an external reset 
switch for three seconds. The ignition control will 
clear all error codes and enter Standby Mode. During 
Lockout Manual Reset, the Diagnostic LED on the 
ignition control flashes red and orange, and the Reset 
Light remains on until the ignition control is reset. 
After the Reset Light turns off, stop pressing the 
switch. Holding the reset for three seconds after 
lockout has been cleared will cause a fault and result in 
entering Lockout Mode again.